Improvement studies on neutron-gamma separation in HPGe detectors by using neural networks

نویسندگان

  • Serkan Akkoyun
  • Tuncay Bayram
  • S. Okan Kara
چکیده

The neutrons emitted in heavy-ion fusion-evaporation (HIFE) reactions together with the gamma-rays cause unwanted backgrounds in gamma-ray spectra. Especially in the nuclear reactions, where relativistic ion beams (RIBs) are used, these neutrons are serious problem. They have to be rejected in order to obtain clearer gamma-ray peaks. In this study, the radiation energy and three criteria which were previously determined for separation between neutron and gamma-rays in the HPGe detectors have been used in artificial neural network (ANN) for improving of the decomposition power. According to the preliminary results obtained from ANN method, the ratio of neutron rejection has been improved by a factor of 1.27 and the ratio of the lost in gamma-rays has been decreased by a factor of 0.50.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

ساخت و آزمایش آشکارساز ترموپیلی نوترون در ستون حرارتی رآکتور تحقیقاتی تهران

Upon increasing needs and vast application of neutron detectors, especially in nuclear reactors and growing number of linear accelerators, design and manufacturing of neutron detectors is a serious demand. The aim of this project is building neutron detectors capable of compensating gamma and temperature response in a radiation media. A special thermocouple coated with Boron carbide at the junc...

متن کامل

The Better Efficiency Calibration for HPGe Detector by Comparing the Single Point Gamma Sources and Multi-nuclides Gamma Source for k0-NAA Method

To obtain high quality of results in gamma spectrometry, it is necessary to calibrate energy and efficiency of gamma detector as accurate as possible. To achieve this aim, utilizing the convenient gamma source can be very useful. Therefore, purpose of present study was to evaluate the determined efficiency by single point gamma sources and multi-nuclides gamma source in a high purity germanium ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره abs/1304.3209  شماره 

صفحات  -

تاریخ انتشار 2013