PURPOSE To compare fast spin-echo (FSE) and fast fluid-attenuated inversion recovery (FLAIR) sequences with conventional spin-echo (CSE) MR imaging in the quantification of the number and volume of multiple sclerosis lesions. METHODS In 30 patients with relapsing-remitting multiple sclerosis, we calculated the total number and volume of lesions detected with each of the three sequences using a semiautomated program. RESULTS On CSE sequences, we calculated a total of 2,583 lesions with a global volume of 836.3 cm3. With FSE sequences, we observed a 16% relative reduction in the number of lesions detected and a 25% relative reduction in global volume as compared with CSE. With fast FLAIR sequences, we detected a significantly lower number and volume of infratentorial lesions, whereas at the cortical/subcortical level the lesions were both more numerous and bulkier than on CSE sequences. Finally, we observed a higher lesion/white matter contrast, a significant reduction in time required for the quantification of lesion load, and a very low interobserver variability in favor of fast FLAIR sequences. CONCLUSION Despite its limitations in the detection of infratentorial lesions, the fast FLAIR sequence in conjunction with a semiautomated quantification program provides a reliable means to evaluate the total lesion burden in patients with MS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions.

PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...

متن کامل

Comparison of T2-weighted and fluid-attenuated inversion-recovery fast spin-echo MR sequences in intracerebral AIDS-associated disease.

PURPOSE To compare the value of fast fluid-attenuated inversion-recovery (FLAIR) with T2-weighted fast spin-echo MR imaging in the detection of acquired immunodeficiency virus (AIDS)-related lesions of the brain. METHODS Forty-four human immunodeficiency virus (HIV)-positive patients were examined with both sequences on either a 1.0-T or a 1.5-T MR system. The number, size, location, and cons...

متن کامل

Fast fluid-attenuated inversion-recovery MR of intracranial infections.

PURPOSE To assess the usefulness of fast fluid-attenuated inversion-recovery (FLAIR) MR sequences in the diagnosis of intracranial infectious diseases. METHODS We compared fast FLAIR images with conventional spin-echo images (T1- and T2-weighted) obtained in 20 patients with infectious diseases (six with encephalitis, five with brain abscesses, three with meningitis, two with meningoencephali...

متن کامل

The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.

PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...

متن کامل

Memory dysfunction in multiple sclerosis corresponds to juxtacortical lesion load on fast fluid-attenuated inversion-recovery MR images.

BACKGROUND AND PURPOSE MR imaging is a sensitive diagnostic tool and paraclinical marker of disease activity and prognosis in multiple sclerosis (MS), yet the role of MR imaging of MS is controversial. The aim of this study was to describe the relationship between cognitive function and MS lesion size and position, as shown on comparative images from conventional spin-echo (CSE) and fast fluid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 1997