High-Resolution Measurement of Volatile Organic Compounds Dissolved in Seawater Using Equilibrator Inlet-Proton Transfer Reaction-Mass Spectrometry (EI-PTR-MS)
نویسندگان
چکیده
We have developed an equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTRMS) system for the high-resolution measurement of the concentrations of multiple volatile organic compounds (VOCs) dissolved in seawater. The equilibration of six VOCs (dimethyl sulfide (DMS), isoprene, propene, acetone, acetaldehyde, and methanol) between seawater samples and the carrier gas, and the response time of the system, were evaluated by means of a series of laboratory experiments. Although equilibrium between the seawater sample and the carrier gas in the equilibrator was not achieved for isoprene and propene (likely because of their low water solubility), the other species did reach equilibrium. The EI-PTR-MS system was deployed during a research cruise in the western North Pacific Ocean. An evaluation of several seawater sampling methods indicated that there was no significant contamination from the sampling apparatus for the target VOCs. For DMS and isoprene, a comparison of EI-PTR-MS measurements with measurements obtained with a membrane equilibrator-gas chromatography/mass spectrometry system showed generally good agreement. EI-PTR-MS captured the temporal variations of dissolved VOCs, including small-scale variability, which demonstrates that the performance of the EI-PTR-MS system was sufficient for simultaneous and continuous measurements of multiple VOCs of environmental importance in seawater.
منابع مشابه
Advanced off-gas measurement using proton transfer reaction mass spectrometry to predict cell culture parameters
Background Mass spectrometry is a well-known technology to detect O2 and CO2 in the off-gas of cell culture fermentations. In contrast to classical mass spectrometers, the proton transfer reaction mass spectrometer (PTR MS) enables the noninvasive analysis of a broad spectrum of volatile organic compounds (VOCs) in real time. The thereby applied soft ionization technology generates spectra of l...
متن کاملPtr-ms Technology for Process Monitoring and Control in Biotechnology
Process monitoring is becoming increasingly relevant in biotechnology, especially in the manufacturing sector to promote cost-effective production. Proton transfer reaction mass spectrometry (PTR-MS) is a well established analytical tool for the measurement of volatile organic compounds (VOCs) and offers fast, real-time detection and quantification of VOCs at trace concentrations. In addition, ...
متن کاملMonoterpene separation by coupling proton transfer reaction time-of-flight mass spectrometry with fastGC.
Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, s...
متن کاملInvestigation of Volatiles Emitted from Freshly Cut Onions (Allium cepa L.) by Real Time Proton-Transfer Reaction-Mass Spectrometry (PTR-MS)
Volatile organic compounds (VOCs) in cut onions (Allium cepa L.) were continuously measured by PTR-MS during the first 120 min after cutting. The headspace composition changed rapidly due to the very reactive volatile sulfurous compounds emitted from onion tissue after cell disruption. Mass spectral signals corresponding to propanethial S-oxide (the lachrymatory factor) and breakdown products o...
متن کاملEddy covariance emission and deposition flux measurements using proton transfer reaction – time of flight – mass spectrometry (PTR-TOF-MS): comparison with PTR-MS measured vertical gradients and fluxes
During summer 2010, a proton transfer reaction – time of flight – mass spectrometer (PTR-TOF-MS) and a quadrupole proton transfer reaction mass spectrometer (PTR-MS) were deployed simultaneously for one month in an orange orchard in the Central Valley of California to collect continuous data suitable for eddy covariance (EC) flux calculations. The high time resolution (5 Hz) and high mass resol...
متن کامل