Control of Grid-Connected and Intentional Islanding Operations of Photo Voltaic System

نویسندگان

  • Ch. Srinivas
  • Rama Prasad Reddy
چکیده

Existing control techniques for DG systems are designed to operate a system either in the connected or disconnected (islanding) mode to the utility; thus not allowing for both modes to be implemented and transitioned between. Existing detection and re-closure algorithms can also be improved upon. Dependent upon the method implemented, detection algorithms can either cause distortions in the output or completely miss a disturbance. The present reclosure process to reconnect to the utility is to completely shut-down and wait five minutes. The proposed methods of this study improve upon existing methods, via simulation and hardware experimentation, for DG systems that can intentionally islanding themselves. In this paper, the control, islanding detection, load shedding, and reclosure algorithms have been proposed for the operation of grid-connected and intentional-islanding DGs. This paper describes a control strategy that is used to implement grid-connected and intentional-islanding operations of distributed power generation. This paper proposes an intelligent load-shedding algorithm for intentional islanding and an algorithm of synchronization for grid reconnection. A Simulink based model is developed and the simulation results for the proposed model are obtained by using MAT LAB. KeywordsDistributed generation (DG), grid-connected operation, intentional-islanding operation, load shedding, synchronization, photovoltaic cell.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Voltage Profile of the Power System Using PV-STATCOM

This paper presents a novel concept of utilizing the photo voltaic solar farm inverter as STATCOM(Static Compensator), named PV-STATCOM, in order to improve the voltage profile of the power system. The entire STATCOM is able to transmit either active or reactive power into the grid. This system is connected to a 14 BUS IEEE standard grid as a case study to simulate the performance of the system...

متن کامل

Novel application of hybrid Perovskite materials in grid-connected photo-voltaic cells

In this paper, the novel application of organic/inorganic perovskite hybrid materials isproposed for grid-connected Photo-voltaic (PV) cells. The perovskite hybrid cells attracted a lot of interest due to their potential in combining advantages of both components. Looking to the future, there is no doubt that these new generations of hybrid materials, born from the very fruitful activitie...

متن کامل

The Novel Control Method for Photovoltaic Converter to the National Grid

In this paper, a novel control method for photovoltaic converter connection to the national gridis presented, so in addition to the injection control by solar arrays to the grid, this method cancompensate reactive power and harmonics in the load current. The system will be connected inparallel between the grid and load. The proposed system supplies all load power consumption(including active po...

متن کامل

Load Sharing Control of Parallel Inverters with Uncertainty in the Output Filter Impedances for Islanding Operation of AC Micro-Grid

Parallel connection of inverter modules is a solution to increase reliability, efficiency and redundancy of inverters in Micro-Grid system. Proper load sharing among parallel inverters is a key point. The circulating current among the inverters can greatly reduce the efficiency or even cause instability of the system. In this paper, a control strategy for improving the load sharing performance ...

متن کامل

Fuzzy Controller Based 3-phase Inverter for Micro Grid with Induction Motor Drive Application

In this paper author discussed PI and fuzzy controllers with the three phase inverter concept and this converter connected to induction motor drive as load. This presents a unified control strategy that enables both islanded and grid-tied operations of three-phase inverter in distributed generation, with no need for switching between two corresponding controllers or critical islanding detection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013