Energy loss and coronary flow simulation following hybrid stage I palliation: a hypoplastic left heart computational fluid dynamic model.

نویسندگان

  • Jeffrey H Shuhaiber
  • Justin Niehaus
  • William Gottliebson
  • Shaaban Abdallah
چکیده

OBJECTIVES The theoretical differences in energy losses as well as coronary flow with different band sizes for branch pulmonary arteries (PA) in hypoplastic left heart syndrome (HLHS) remain unknown. Our objective was to develop a computational fluid dynamic model (CFD) to determine the energy losses and pulmonary-to-systemic flow rates. This study was done for three different PA band sizes. METHODS Three-dimensional computer models of the hybrid procedure were constructed using the standard commercial CFD softwares Fluent and Gambit. The computer models were controlled for bilateral PA reduction to 25% (restrictive), 50% (intermediate) and 75% (loose) of the native branch pulmonary artery diameter. Velocity and pressure data were calculated throughout the heart geometry using the finite volume numerical method. Coronary flow was measured simultaneously with each model. Wall shear stress and the ratio of pulmonary-to-systemic volume flow rates were calculated. Computer simulations were compared at fixed points utilizing echocardiographic and catheter-based metric dimensions. RESULTS Restricting the PA band to a 25% diameter demonstrated the greatest energy loss. The 25% banding model produced an energy loss of 16.76% systolic and 24.91% diastolic vs loose banding at 7.36% systolic and 17.90% diastolic. Also, restrictive PA bands had greater coronary flow compared with loose PA bands (50.2 vs 41.9 ml/min). Shear stress ranged from 3.75 Pascals with restrictive PA banding to 2.84 Pascals with loose banding. Intermediate PA banding at 50% diameter achieved a Qp/Qs (closest to 1) at 1.46 systolic and 0.66 diastolic compared with loose or restrictive banding without excess energy loss. CONCLUSIONS CFD provides a unique platform to simulate pressure, shear stress as well as energy losses of the hybrid procedure. PA banding at 50% provided a balanced pulmonary and systemic circulation with adequate coronary flow but without extra energy losses incurred.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of mathematical modeling to compare and predict hemodynamic effects between hybrid and surgical Norwood palliations for hypoplastic left heart syndrome.

BACKGROUND Combining bilateral pulmonary artery banding with arterial duct stenting, the hybrid approach achieves stage 1 palliation for hypoplastic left heart syndrome with different flow characteristics than those after the surgical Norwood procedures. Accordingly, we used computational modeling to assess some of these differences, including influence on systemic and cerebral oxygen deliverie...

متن کامل

Hybrid Palliation for Neonates With Hypoplastic Left Heart Syndrome: Current Strategies and Outcomes

In the last decade the hybrid procedure has emerged as an alternative stage I palliation in neonates with hypoplastic left heart syndrome (HLHS). This review discusses the historical aspect, surgical and interventional techniques, current outcomes and future direction of this procedure. Hybrid palliation yields equivalent but not superior stage I palliation survival and comparable 1-year surviv...

متن کامل

Pediatric Cardiovascular Surgery

Hybrid stage I palliation combines cardiothoracic surgery and interventional transcatheter procedures for treatment of hypoplastic left heart syndrome. The approach is an alternative to the Norwood procedure, the traditional first stage of surgical palliation. Hybrid stage I palliation involves placing bilateral branch pulmonary artery bands and a patent ductus arteriosus stent through a median...

متن کامل

The current role of hybrid procedures in the stage 1 palliation of patients with hypoplastic left heart syndrome.

Hypoplastic left heart syndrome is a relatively common cardiac malformation, accounting for 4-9% of children born with congenital heart disease. Since 1981 the mainstay of treatment has been the Norwood series of operations which have been variously modified, most recently using an RV-PA conduit (Sano shunt). With these surgical modifications and with increased experience in perioperative care ...

متن کامل

Hemodynamic Simulation for Congenital Heart Disease

Hypoplastic left heart syndrome (HLHS) is one kind of congenital heart diseases of newborn. The surgeries for HLHS have to be carried out at very early stage. However, currently there are no quantitative standard to evaluate and predict the outcome of the therapy. In this study, computational fluid dynamics (CFD) is introduced simulate the hemodynamics after Norwood surgery; a first stage surge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2013