Image registration with auto-mapped control volumes.

نویسندگان

  • Eduard Schreibmann
  • Lei Xing
چکیده

Many image registration algorithms rely on the use of homologous control points on the two input image sets to be registered. In reality, the interactive identification of the control points on both images is tedious, difficult, and often a source of error. We propose a two-step algorithm to automatically identify homologous regions that are used as a priori information during the image registration procedure. First, a number of small control volumes having distinct anatomical features are identified on the model image in a somewhat arbitrary fashion. Instead of attempting to find their correspondences in the reference image through user interaction, in the proposed method, each of the control regions is mapped to the corresponding part of the reference image by using an automated image registration algorithm. A normalized cross-correlation (NCC) function or mutual information was used as the auto-mapping metric and a limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm (L-BFGS) was employed to optimize the function to find the optimal mapping. For rigid registration, the transformation parameters of the system are obtained by averaging that derived from the individual control volumes. In our deformable calculation, the mapped control volumes are treated as the nodes or control points with known positions on the two images. If the number of control volumes is not enough to cover the whole image to be registered, additional nodes are placed on the model image and then located on the reference image in a manner similar to the conventional BSpline deformable calculation. For deformable registration, the established correspondence by the auto-mapped control volumes provides valuable guidance for the registration calculation and greatly reduces the dimensionality of the problem. The performance of the two-step registrations was applied to three rigid registration cases (two PET-CT registrations and a brain MRI-CT registration) and one deformable registration of inhale and exhale phases of a lung 4D CT. Algorithm convergence was confirmed by starting the registration calculations from a large number of initial transformation parameters. An accuracy of approximately 2 mm was achieved for both deformable and rigid registration. The proposed image registration method greatly reduces the complexity involved in the determination of homologous control points and allows us to minimize the subjectivity and uncertainty associated with the current manual interactive approach. Patient studies have indicated that the two-step registration technique is fast, reliable, and provides a valuable tool to facilitate both rigid and nonrigid image registrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound

The orientation of cardiac fibers affects the anatomical, mechanical, and electrophysiological properties of the heart. Although echocardiography is the most common imaging modality in clinical cardiac examination, it can only provide the cardiac geometry or motion information without cardiac fiber orientations. If the patient's cardiac fiber orientations can be mapped to his/her echocardiograp...

متن کامل

Physics Contribution Comparison of Intensity-modulated Radiotherapy Planning Based on Manual and Automatically Generated Contours Using Deformable Image Registration in Four-dimensional Computed Tomography of Lung Cancer Patients

Purpose: To evaluate the implications of differences between contours drawn manually and contours generated automatically by deformable image registration for four-dimensional (4D) treatment planning. Methods and Materials: In 12 lung cancer patients intensity-modulated radiotherapy (IMRT) planning was performed for both manual contours and automatically generated (‘‘auto’’) contours in mid and...

متن کامل

[Two-step image registration based on control volumes].

OBJECTIVE To increase the accuracy of beam targeting and improve the dose distributions in radiotherapy using a robust image registration algorithm based on control volumes. METHODS Control volume mapping and thin-plate spline deformable transformation were combined. The use of the control volumes increased the accuracy for the deformable registration. A bi-directional mapping method was also...

متن کامل

Interactive Registration of Intracellular Volumes with Radial Basis Functions

We propose a novel approach to 3D image registration of intracellular volumes. The approach extends a standard image registration framework to the curved cell geometry. An intracellular volume is mapped onto another intracellular domain by using two pairs of point set surfaces approximating their nuclear and plasma membranes. The mapping function consists of the affine transformation, tetrahedr...

متن کامل

Auto-align - Multi Modality Fluorescence Microscopy Image Co-registration Auto-align image co-registration

1 Physical Sciences of Imaging in the Biomedical Sciences (PSIBS) doctoral training centre, University of Birmingham Edgbaston Birmingham, B15 2TT, UK. 2 School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK. 3 School of Computer Science, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK. * Corresponding authors: Joshua Z. Rappoport 2 , j.rappoport@bham....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2006