Numerical Models of an Artery with a Net Structured Stent
نویسندگان
چکیده
Main cause of restenosis after balloon angioplasty is due to the stresses generated in the artery as well as from the stent artery interaction. Understanding the factors that are involved in this interaction, and the ability to evaluate the stresses that are formed in the artery, could help to lessen the number of failures. The goal of the present study is to develop computationally efficient numerical models for estimating the Damage Factor (DF) as the contact stresses, and to investigate their influence upon stent design, artery and plaque parameters. At first the artery was taken as a hollow cylinder with homogenous, linear elastic properties of the material. Later, the artery was taken as a two dissimilar layers model, with non-linear hyper-elastic properties. The variation in the Damage Factor value as a function of the mismatch between stent’s and artery’s diameters is nearly linear, and as much as the diameter of the artery increases, the Damage Factor for the same mismatch decreases. For arteries with 75% blocking and mismatch of 1mm, the Damage Factor is 3.8.
منابع مشابه
Numerical models of net-structure stents inserted into arteries
INTRODUCTION Restenosis is strongly attributed to stresses caused by stent-artery interactions generated in the artery after balloon angioplasty. Numerical methods are often used to examine the stent-artery mechanical interactions. To overcome the extensive computational requirements demanded by these simulations, simplifications are needed. OBJECTIVE We introduce simplified models to calcula...
متن کاملManagement of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction
Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent
متن کاملSubclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملNumerical Models of an Artery with Different Stent Types
Main cause of restenosis after balloon angioplasty is due to the stresses generated in the artery as well as from the stent artery interaction. Understanding the factors that are involved in this interaction, and the ability to evaluate the stresses that are formed in the artery, could help to lessen the number of failures. The goal of the present study is to develop computationally efficient n...
متن کاملگزارش یک مورد آنژیوپلاستی و Stent گذاری موفق در درمان تنگی
Introduction: Renal transplantation has established itself as the treatment of choice for the majority of patients with End stage renal failure(ESRF). Arterial stenosis is the most common vascular complication after kidney transplantation, occurring in approximately 4%-25% of transplant recipients. Case Report: The patient is a 68 year old man with ESRF due to Poly cystic kidney disease(PCK...
متن کامل