Outcomes of 27 Gauge Microincision Vitrectomy Surgery for Posterior Segment Disease.
نویسندگان
چکیده
PURPOSE To report the initial experience, clinical outcomes, and safety profile of 27 gauge pars plana vitrectomy (PPV) in eyes with posterior segment disease. DESIGN Multicenter, retrospective, interventional case series. METHODS setting: Private practice and tertiary care settings. STUDY POPULATION Eyes undergoing 27 gauge PPV for a vitreoretinal surgery indication. INTERVENTION Three-port, transconjunctival 27 gauge PPV. MAIN OUTCOME MEASURES Change in visual acuity and occurrence of intraoperative and postoperative complications with minimum follow-up of 90 days. RESULTS Ninety-five eyes met the inclusion criteria. Surgical indications included epiretinal membrane (n = 26), diabetic tractional retinal detachment (n = 14), full-thickness macular hole (n = 11), rhegmatogenous retinal detachment with (n = 7) or without (n = 9) proliferative vitreoretinopathy (PVR), vitreous hemorrhage (n = 10), vitreous opacities (n = 8), endophthalmitis (n = 4), sub-silicone oil retinal detachment (n = 3), retained lens material (n = 1), submacular hemorrhage (n = 1), and aqueous misdirection (n = 1). Mean logMAR visual acuity improved from 1.08 ± 0.71 (20/240 Snellen equivalent) preoperatively to 0.53 ± 0.65 (20/67 Snellen equivalent) postoperatively (P < .001). Mean follow-up was 144 days (median 127 days, range 90-254 days). There were no intraoperative complications and no case required conversion to 20, 23, or 25 gauge instrumentation. A total of 3 sclerotomy sites (1.1%) were sutured at the conclusion of surgery. Postoperative complications included transient ocular hypertension in 8 eyes (8.4%), transient hypotony in 5 eyes (5.3%), and vitreous hemorrhage in 5 eyes (5.3%). No cases of postoperative endophthalmitis, sclerotomy-related retinal tears, or choroidal detachments were encountered in the follow-up period. CONCLUSION The 27 gauge PPV was well tolerated with low rates of intraoperative and postoperative complications across varied surgical indications.
منابع مشابه
Faster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy
BACKGROUND AND METHODS We compared surgical procedures and outcomes, including duration of recovery period, in eyes with proliferative diabetic retinopathy that underwent 25-gauge microincision vitrectomy surgery with those that underwent 20-gauge vitrectomy. Seventy-two eyes from 53 patients that underwent 20-gauge vitrectomy in 2006 and 87 eyes from 55 patients that underwent 25-gauge vitrect...
متن کاملInnovations in 27 - Gauge Vitrectomy for Sutureless Microincision
T he common thinking regarding surgical wounds is that “much smaller is much better.” Based on this concept, microincision vitrectomy surgery (MIVS) with 25or 23-gauge instruments has taken over from conventional 20-gauge vitrectomy in many cases, and the technology has evolved radically during the past several years. Along with the development of ergonomic instrumentation and new-generation vi...
متن کاملHeads-Up Macular Surgery with a 27-Gauge Microincision Vitrectomy System and Minimal Illumination
OBJECTIVE We combined heads-up 3-dimensional (3D) 27-gauge microincision vitrectomy surgery (27GMIVS) with a very low-intensity illumination system. METHODS This study was based on a retrospective, interventional case series of 6 eyes of 6 patients with macular disease. All patients underwent heads-up 3D 27GMIVS and the power of the intraocular illuminator was set to its minimum level, 1% (ap...
متن کاملIntraoperative Optical Coherence Tomography-Assisted 27-Gauge Vitrectomy in Eyes with Vitreoretinal Diseases
OBJECTIVE To report intraoperative optical coherence tomography (iOCT)-assisted 27-gauge microincision vitrectomy surgery (MIVS) in eyes with vitreoretinal disease. METHODS A retrospective, interventional case series performed at a single center, including 6 eyes with retinal disease that underwent iOCT-assisted 27-gauge MIVS. RESULTS The advantages of iOCT were most notable when it was use...
متن کاملPerioperative changes of the intraocular pressure during the treatment of epiretinal membrane by using 25- or 27-gauge sutureless vitrectomy without gas tamponade
PURPOSE The purpose of this study was to compare perioperative intraocular pressures (IOPs) in 25- or 27-gauge microincision vitrectomy surgery (MIVS) and to evaluate the stability of postoperative sclerotomy closure. MATERIALS AND METHODS This is a retrospective review of 147 eyes treated for epiretinal membrane by using 25- or 27-gauge MIVS as the initial vitrectomy (25-gauge phacovitrectom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of ophthalmology
دوره 164 شماره
صفحات -
تاریخ انتشار 2016