Synchrotron radiation x-ray absorption fine-structure and Raman studies on CdZnTe ternary alloys

نویسندگان

  • Yu Li
  • Larry A. Franks
  • Yu Li Wu
  • Yen-Ting Chen
  • Zhe Chuan Feng
  • Jyh-Fu Lee
  • P. Becla
  • Weijie Lu
  • Francis Bitter
چکیده

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. ABSTRACT The synchrotron radiation (SR) X-ray absorption fine-structure spectroscopy (XAFS) technology has been employed to obtained Zn K-edge absorption spectra for Cd 1−x Zn x Te alloy with x = 0.03, 0.10, 0.20, 0.30, 0.40, 0.50 and 1.00. Their Fourier transform spectra were analyzed, which have shown a bimodal distribution of bond lengths, suggesting distortion of the Te sub-lattice, so that the linear interpolation is true only in an approximate sense. Synthetic CdZnTe crystals can be used for the room temperature-based detection of gamma radiation. The radiation detection properties of CZT crystals vary widely. A common defect found in most high-quality CZT crystals is Te secondary phases, often located along grain boundaries. The secondary phases can be both large inclusions (>50 μm) and smaller precipitates (<50 μm). The Te secondary phases distributed throughout the crystal can cause changes to the detector leakage current, resulting in decreased radiation spectrometer performance. This set of Cd 1-x Zn x Te crystals were also measured by Raman scattering at room temperature. The two observed peaks at about 125 and 145 cm-1 which can be assigned to Te A 1 and E phonon mode, respectively. The induced damage on the crystal surfaces by Raman laser has been discussed. It is suggested that in the case of highly Zn doping CdZnTe crystals, the ZnTe bond were broken by laser exposing and then free Te atoms are migrating to these heated areas which cause Te precipitate. Further, the results of the soft X-ray measurements have been also presented and this part of the experimental data needs to do more penetrating analysis in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of High Indium InXGa1-XN Alloys with Synchrotron Radiation

InGaN thin films with near entire indium composition range have been successfully grown on GaN/sapphire (0001) by molecular beam epitaxy (MBE). X-ray absorption fine structure have been used to study the local structure of some typical InxGa1-xN alloys with high indium (In) composition of x=0.78 and 0.86. A detailed analysis of the extended x-ray absorption fine structure of In K-edge by using ...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

Magnetic X-ray absorption fine structure for Ni-Mn alloys.

Magnetic X-ray absorption fine-structure (XAFS) spectra have been measured for Ni-Mn alloys. The magnetic XAFS in the near-edge region (X-ray absorption near-edge structure, XANES) and X-ray magnetic circular dichroism (XMCD) of the Mn and Ni K-edge for Ni(1-x)Mn(x) (x = 0.25, 0.24 and 0.20) show that (i) the local magnetic structure around the Mn atom is quite different from that around the Ni...

متن کامل

Nanoparticles and nanowires: synchrotron spectroscopy studies

This paper reviews the research in nanomaterials conducted in our laboratory in the last decade using conventional and synchrotron radiation techniques. While preparative and conventional characterisation techniques are described, emphasis is placed on the analysis of nanomaterials using synchrotron radiation. Materials of primary interests are metal nanoparticles and semiconductor nanowires an...

متن کامل

A new on-axis multimode spectrometer for the macromolecular crystallography beamlines of the Swiss Light Source

X-ray crystallography at third-generation synchrotron sources permits tremendous insight into the three-dimensional structure of macromolecules. Additional information is, however, often required to aid the transition from structure to function. In situ spectroscopic methods such as UV-Vis absorption and (resonance) Raman can provide this, and can also provide a means of detecting X-ray-induced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009