Influence of Resin Cements on the Tension Force of Cast Frameworks Made by the Technique of Framework Cemented on Prepared Abutments.
نویسندگان
چکیده
This study evaluated the tension force of cast frameworks made by the technique of framework cemented on prepared abutments using two different resin cements. Forty multi-unit abutment analogs were individually fixed with chemically cured acrylic resin inside PVC cylinders using a parallelometer. Brass cylindrical abutments were tightened to the multi-unit abutments to be used as spacers and then castable UCLA abutments were positioned above. These abutments were cast with Ni-Cr and then divided into 4 groups (n=10): cemented with RelyX U100(r); cemented with RelyX U100(r) and simulation of acrylic resin polymerization process; cemented with Multilink(r); and cemented with Multilink(r) and simulation of acrylic resin polymerization process. Abutments were cemented according to manufacturers' instructions. In a universal testing machine, tensile strength was applied in the direction of the long axis of the abutments at 1 mm/min crosshead speed until displacement of the luted abutments was obtained. The values of maximum tensile force (N) required for the displacement of the luted abutments were tabulated and analyzed statistically by one-way ANOVA with a 95% confidence level. No statistically significant difference was found among the groups (p>0.05). There was an increase in mean tension force when the specimens were subjected to the simulation of acrylic resin polymerization process, but the results did not differ statistically. Both resin cements presented positive results as regards the retention of luted abutments on their respective multi-unit abutments. Both materials may be indicated for the technique of framework cemented on prepared abutments when professionals pursuit better adaptation of implant-supported frameworks.
منابع مشابه
Retention of cast crown copings cemented to implant abutments.
BACKGROUND The cementation of crowns to dental implant abutments is an accepted form of crown retention that requires consideration of the properties of available cements within the applied clinical context. Dental luting agents are exposed to a number of stressors that may reduce crown retention in vivo, not the least of which is occlusal loading. This study investigated the influence of compr...
متن کاملEffects of proximal grooves and abutment height on the resistance of resin-cemented crowns in teeth with inadequate resistance: An in vitro study.
BACKGROUND The resistance form is a key factor for a successful crown fabrication. This in vitro study evaluates the effects of proximal grooves and abutment height on the resistance of single cast crowns in molars with inadequate resistance. METHODS Sixty extracted human molars were prepared to possess 20° of total occlusal convergence for single crown fabrication. All of the prepared teeth ...
متن کاملRetentiveness of dental cements used with metallic implant components.
There is limited dental literature evaluating the retentive capabilities of luting agents when used between metal components, such as cast metal restorations cemented onto machined metal implant abutments. This study compared the retentive strengths of 5 different classes of luting agents used to cement cast noble metal alloy crowns to 8-degree machined titanium cementable implant abutments fro...
متن کاملEvaluation of the Effect of Sodium Hypochlorite Irrigant on Pull-out Bond Strength of FRC Posts Using Different Resin Cements
Introduction: To evaluate the effects of using sodium hypochlorite irrigant on pull-out bond strength of self-etch and self-adhesive resin cements to dentin. Methods: Sixty intact premolars were decoronated and the root canals were prepared by step-back technique. The teeth were divided into two groups according to the irrigant used during root canal treatment: 5.25% sodium hypochlorite and nor...
متن کاملEvaluation of Tensile Bond Strength between Dentin and Metallic Copings Using Different Resin Cements
Statement of the Problem: For a successful clinical outcome, luting agents should have a high bond strength. Bond failure is still one of the main reasons of restoration failures. Purpose: The present study was designed to comparatively evaluate the retention of metallic copings using different resin luting cements. Materials and Method: In the present experimental study, 40 intact premolar tee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 26 4 شماره
صفحات -
تاریخ انتشار 2015