Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.

نویسندگان

  • Abraham Rosenbaum
  • Christopher Kirby
  • Peter H Breen
چکیده

BACKGROUND The authors have developed a new clinical bymixer that bypasses a constant fraction of gas flow through a mixing arm. A separate bymixer was interposed in the expiratory and inspiratory limbs of the ventilation circuit to measure mixed gas fractions. By utilizing nitrogen conservation, the clinical bymixer allows the determination of airway carbon dioxide elimination (VCO2) and oxygen uptake (VO2), whenever basic expired flow and gas monitoring measurements are used for the patient. Neither an expiratory exhaust gas collection bag nor expensive, complex equipment are needed. This study tested the accuracy of airway bymixer-flow measurements of VCO2 and VO2 in a new bench apparatus. METHODS The authors compared airway bymixer-flow measurements of VCO2 and VO2 over a range of reference values generated by ethanol combustion in a new metabolic lung simulator, which was ventilated by a volume-cycled respirator. An airway humidity and temperature sensor permitted standard temperature and pressure, dry, correction of airway VCO2 and VO2. RESULTS Bymixer-flow airway measurements of VCO2 and VO2 correlated closely (R2 = 0.999 and 0.998, respectively) with the stoichiometric values generated by ethanol combustion. Limits of agreement for VCO2 and VO2 were 0.1 +/- 4.7 and 1.1 +/- 5.7%, respectively. The average (+/- SD) percent error for airway VCO2 (compared with the stoichiometric value) was 0.1 +/- 2.4%. The same error for airway VO2 was 1.1 +/- 2.9%. CONCLUSIONS The new clinical bymixer, plus basic expired flow and gas fraction measurements, generated clinically accurate determinations of VCO2 and VO2. These measurements are helpful in the assessment of metabolic gas exchange in the critical care unit. In contrast to using the gas collection bag or complex metabolic monitor, the bymixer should measure mixed gas concentrations in the inspired or expired limb of the common anesthesia circle ventilation circuit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Accurate Metabolic Simulator for Indirect Calorimetry System Validation

A metabolic simulator capable of simulation of respiratory oxygen consumption (VO2) and carbon dioxide production (VCO2) for validation of indirect calorimetry systems is described. The metabolic simulator adds/removes respiratory gases by way of mass flow controllers to/from a physiologically realistic lung simulator (Michigan Instruments Inc. Training/Test Lung). The metabolic simulator and M...

متن کامل

Novel, adjustable, clinical bymixer measures mixed expired gas concentrations in anesthesia circle circuit.

UNLABELLED We have introduced a novel, parallel design into a new clinical bymixer (patent pending), named for the bypass of a constant fraction of total flow through a mixing chamber. Over a wide range of tidal volumes (300-1200 mL), frequency (6-20 breaths/min), and PCO(2) (6-50 mm Hg), the bymixer provided accurate measurement of mixed expired gas fractions in the ventilation circuit compare...

متن کامل

Continuous measurement of gas uptake and elimination in anesthetized patients using an extractable marker gas.

Measurement of pulmonary gas uptake and elimination is often performed, using nitrogen as marker gas to measure gas flow, by applying the Haldane transformation. Because of the inability to measure nitrogen with conventional equipment, measurement is difficult during inhalational anesthesia. A new method is described, which is compatible with any inspired gas mixture, in which fresh gas and exh...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 100 6  شماره 

صفحات  -

تاریخ انتشار 2004