Aging Assessment of Power Transformer Using Multi-parameters
نویسندگان
چکیده
As the population of transformers in service increases and their operating time extends, much attention has been focused on their availability and reliability. However, insufficient research work concentrates on how to evaluate transformer’s aging condition, although huge progress has been made on the techniques of fault diagnosis and condition assessment of transformer in past decades. This paper presents the concept of Aging Index (AI), which is a practical tool that combines the results of routine inspections, and site and laboratory testing to estimate the aging condition of oil-immersed transformers. Further, frequency domain spectroscopy (FDS) as a novel non-destructive testing technique to estimate remained life expectancy is included in aging evaluation system. Moreover, a software system based on transformer’s electrical and thermal parameters is developed correspondingly, by using a multi-parameters analytic approach. This system would dedicate to decision-making and replacement planning and has good application prospects.
منابع مشابه
Protection Scheme of Power Transformer Based on Time–Frequency Analysis and KSIR-SSVM
The aim of this paper is to extend a hybrid protection plan for Power Transformer (PT) based on MRA-KSIR-SSVM. This paper offers a new scheme for protection of power transformers to distinguish internal faults from inrush currents. Some significant characteristics of differential currents in the real PT operating circumstances are extracted. In this paper, Multi Resolution Analysis (MRA) is use...
متن کاملWind Turbine Transformer Optimum Design Assuming a 3D Wound Core
A wind turbine transformer (WTT) is designed using a 3D wound core while the transformer’s total owning cost (TOC) and its inrush current performance realized as the two objective functions in a multi-objective optimization process. Multi-objective genetic algorithm is utilized to derive Pareto optimal solutions. The effects of inrush current improvement on other operating and design parameters...
متن کاملمدلسازی اثر بارگذاری بر قابلیت اطمینان ترانسفورمر
Transformer is one of the most important components of power system, which determining its reliability is very important. To evaluate transformer overall reliability, in addition to probability of failures occur due to chance events, the probability of failures owing to aging should be taken into account. To determine transformer reliability in aging area, estimating its remaining life is of gr...
متن کاملAging Study of Transformer Oil-Impregnated Repulped and Standard Cellulose by Measuring of 2-furfural Content of the Oil
In order to evaluate the reliability of using repulped cellulose in transformers, the aging process was applied on standard and repulped cellulose in a laboratory accelerated model by increasing of temperature to 150 ° C and their behavior was monitored by measuring the amount of 2-furfural released in oil by HPLC (High Performance Liquid Chromatography) in the consecutive aging periods and...
متن کاملReliability Model of Power Transformer with ONAN Cooling
Reliability of a power system is considerably influenced by its equipments. Power transformers are one of the most critical and expensive equipments of a power system and their proper functions are vital for the substations and utilities. Therefore, reliability model of power transformer is very important in the risk assessment of the engineering systems. This model shows the characteristic...
متن کامل