The ISFET based heparin sensor with a monolayer of protamine as affinity ligand.

نویسندگان

  • J C van Kerkhof
  • P Bergveld
  • R B Schasfoort
چکیده

The ion-step measuring method was used to determine absolute heparin concentrations in PBS and blood plasma with a Ta2O5 ISFET on to which a monolayer of protamine had been immobilized. Heparin is a highly negatively charged polysaccharide, which is used clinically to delay the clotting of blood. Protamine acts as an affinity ligand for heparin. The response of the ISFET system on a step-wise increase in the electrolyte concentration (a so-called ion-step) is a transient change of the output voltage, which is related to the surface charge density of the ISFET gate oxide. After 2 mins of incubation in a plasma sample containing heparin, the amplitude of the transient ISFET response to an ion-step showed a linear relation to the heparin concentration. In blood plasma, heparin concentrations between 0.3 and 2.0 Units/ml could be determined with an accuracy of +/- 0.08 Units/ml. Heparin concentrations in different plasma samples of heparinized patients were determined and compared with the APTT. No direct relation was found between the APTT and the heparin concentration, but this result was not surprising.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an ISFET based heparin sensor using the ion-step measuring method

The ion-step measuring method was used to determine heparin concentrations in PBS and blood plasma. Heparin is a sulphated polysaccharide which is clinically used as a drug to prevent the clotting of blood. The measuring method is based on detection of changes in charge density in a porous membrane which is deposited on the gate of an ISFET. Protamine was used as affinity ligand in the membrane...

متن کامل

Comparison between complications of vascular surgery procedures with and without aPPT assessment and protamine sulfate reversal

 Abstract Background: Thrombosis will occur due to contact of blood with unepithelialized surfaces after vascular clamping and also blood stasis during vascular surgery. Heparin is administered to prevent thrombosis. The aPTT test is used for assurance of the anticoagulative effect of heparin. At the end of the operation heparin is neutralized by protamine sulfate in some centers. In this study...

متن کامل

بررسی وجود هپارین تزریق شده حین عمل جراحی عروق در خون بیماران قبل از خنثی کردن آن توسط

Heparine is a anticoagulation substance used in vascular surgery to prevent thrombosis during opration and after a while becomes neutralized by protamin an antiheparin drug. Protamine causes some dangerous complications including cardiovascular collapse, anaphilactoid reation, hypotention, bradycardia and bronchospasm. Using higher doses, also protamine leads to increase anticoagolation e...

متن کامل

Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration.

An improved protamine-sensitive electrode based on a polymeric membrane doped with the charged ion exchanger dinonylnaphthalenesulfonate (DNNS) is used for monitoring heparin concentrations in whole blood. The electrode exhibits significant nonequilibrium potentiometric response to polycationic protamine over the concentration range of 0.5-20 mg/L in undiluted whole-blood samples. The sensor ca...

متن کامل

Low Molecular Weight Heparin Overdose: A 10 Year Case Series

  Background: Low molecular weight heparin (LMWH) is used for the treatment and prevention of coagulative disorders. Few patients receiving therapeutic doses of LMWH develop major hemorrhage. Currently there are few reports in the literature on acute overdose on adults.  In this study, clinical profile, treatment and outcome of 21 patients who acutely overdosed enoxaparin are described. Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 10 3-4  شماره 

صفحات  -

تاریخ انتشار 1995