Efficacy of Computed Tomography (CT) Attenuation Values and CT Findings in the Differentiation of Pleural Effusion

نویسندگان

  • Kadihan Yalçin-Şafak
  • Neslihan Umarusman-Tanju
  • Muhammet Ayyıldız
  • Nihal Yücel
  • Tamer Baysal
چکیده

BACKGROUND The aim of this study was to investigate the efficacy of computed tomography (CT) findings for characterizing pleural effusions with the use of attenuation values. MATERIAL/METHODS One hundred and twenty eight patients with pleural effusions on thoracic CT who underwent thoracentesisis within two weeks were studied. Pleural effusions were classified as exudates or transudates according to the Light's criteria. A region of interest was placed for the measurement of Hounsfield Unit (HU) values in the area of the greatest amount of effusion on each slice of the three slices used. CT features that were evaluated for distinguishing pleural exudates from transudates included pleural nodules, pleural thickening and loculation. RESULTS Thirty three (26%) of the 128 pleural effusions were transudates and 95 (74%) were exudates. The mean HU values of the exudates (8.82±7.04) were significantly higher than those of the transudates (2.91±8.53), (p<0.001). No statistically significant difference was found between transudate and exudate patients in terms of pleural thickness, pleural nodules and loculation (p>0.05). CONCLUSIONS HU values can help in differentiating exudative pleural effusions from transudative pleural effusions. Because of overlapping HU values, correlation with clinical findings is essential.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion.

PURPOSE We aimed to evaluate the efficacy of multidetector computed tomography (CT) imaging in diagnosis of pleural exudates and transudates using attenuation values. MATERIALS AND METHODS This retrospective study included 106 patients who were diagnosed with pleural effusion between January 2010 and June 2012. After the patients underwent chest CT, thoracentesis was performed in the first we...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Incidental Findings in Patients Evaluated for Pulmonary Embolism Using Computed Tomography Angiography

Introduction: Pulmonary embolism (PE) is a common lethal disease that its clinical symptoms may be seen in many other diseases. Computed tomography pulmonary angiography (CTPA) is a valuable diagnostic modality for detection of PE. In addition, it can accurately detect the other diseases with clinical symptoms similar to PE. The aim of this study is to evaluate the frequency of PE and nonemboli...

متن کامل

Differentiation between malignant and benign pleural effusion in patients with extra-pleural primary malignancies: assessment with positron emission tomography-computed tomography.

OBJECTIVES We sought to define an accurate diagnostic approach for differentiating benign from malignant pleural effusion on positron emission tomography-computed tomography (PET-CT). MATERIAL AND METHODS PET-CT studies of 31 patients with primary extrapleural malignancy and pleural effusion were reviewed retrospectively. CT parameters assessed were size and density (Hounsfield units, or HU) ...

متن کامل

An iterative method to estimate x-ray attenuation coefficients in computed tomography

Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2017