Functional evaluation of the medtronic stentless porcine xenograft mitral valve in sheep.
نویسندگان
چکیده
BACKGROUND Recently, renewed interest in allograft and stentless "freehand" bileaflet xenograft mitral valve replacement has arisen. The variability of human papillary tip anatomy and scarcity of donors limit allograft availability, making xenograft mitral valves an attractive alternative; however, these valves require new surgical implantation techniques, and assessment of their hemodynamics and functional geometry is lacking. METHODS Seven sheep underwent implantation of a new stentless, glutaraldehyde-preserved porcine mitral valve (Physiological Mitral Valve [PMV], Medtronic) and were studied acutely under open-chest conditions. A new method of retrograde cardioplegia was developed. Hemodynamic valve function was assessed by epicardial Doppler echocardiography. 3D motion of miniature radiopaque markers sutured to the valve leaflets, annulus, and papillary tips was measured. Six other sheep with implanted markers served as controls. RESULTS Both papillary muscle tips avulsed in the first animal, leaving 6 other animals. Mitral regurgitation was not observed in any xenograft valve. The peak and mean transvalvular gradients were 4.6+/-1.8 mm Hg and 2.6+/-1.5 mm Hg, respectively. The average mitral valve area was 5.7+/-1.6 cm(2). Valve closure in the xenograft group occurred later (30+/-11 ms, P<0. 015) and at higher left-ventricular pressure (61+/-9 mm Hg, P<0.001) than in the control group; furthermore, leaflet coaptation was displaced more apically (5.6+/-2.2 mm, P<0.001) and septally (5. 8+/-1.5 mm, P<0.001), and the anterolateral papillary tip underwent greater septal-lateral displacement (2.7+/-1.5 mm, P<0.001). Annular contraction during the cardiac cycle was similar in the 2 groups (xenograft 9.2+/-4.5% versus control 10.6+/-4.5% [mean+/-SD; 2-factor ANOVA model]). CONCLUSIONS Successful freehand stentless porcine mitral valve implantation is feasible in sheep and was associated with excellent early postoperative hemodynamics. Physiological mitral valve annular contraction and functional leaflet closure mechanics were preserved. Long-term valve durability, calcification, and hemodynamic performance remain to be determined in models.
منابع مشابه
Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.
BACKGROUND AND AIM OF THE STUDY The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves...
متن کامل[Aortic valve replacement with a Cryolife O'Brien stentless bioprosthesis].
INTRODUCTION AND OBJECTIVES The Cryolife O'Brien xenograft is a stentless bioprosthesis constructed from noncoronary leaflets from three porcine aortic valves. The aim of this study was to investigate short-term results after aortic valve replacement with this composite xenograft. METHODS Since October 1993, Cryolife O'Brien bioprostheses have been implanted in 210 patients. The patients' mea...
متن کاملTissue engineering of an auto-xenograft pulmonary heart valve.
To improve the durability of stentless valves without losing their excellent hemodynamic function, a new-generation auto-xenograft was developed and evaluated. A piece of vein was harvested from 3 juvenile sheep 6 weeks before implantation of the valve. Endothelial cells from the vein material were cultivated and used to reendothelialize a decellularized porcine pulmonary valve. The tissue-engi...
متن کاملLongevity after aortic root replacement: is the mechanically valved conduit really the gold standard for quinquagenarians?
BACKGROUND The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. METHODS AND RESULTS A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, ...
متن کاملStructural Valve Deterioration After Aortic Valve Replacement with Medtronic Freestyle Stentless Porcine Aortic Root Bioprostheses
The Medtronic freestyle aortic root bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) is a stentless valve with an effective orifice area that is larger than that observed on other bioprostheses. However, there have been sporadic reports of structural valve deterioration (SVD), such as aortic root wall rupture, leaflet tearing, and pseudoaneurysm formation. We report five cases of SVD of fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 100 19 Suppl شماره
صفحات -
تاریخ انتشار 1999