Incomplete recovery of myocyte contractile function despite improvement of myocardial architecture with left ventricular assist device support.

نویسندگان

  • Amrut V Ambardekar
  • John S Walker
  • Lori A Walker
  • Joseph C Cleveland
  • Brian D Lowes
  • Peter M Buttrick
چکیده

BACKGROUND Unloading a failing heart with a left ventricular assist device (LVAD) can improve ejection fraction (EF) and LV size; however, recovery with LVAD explantation is rare. We hypothesized that evaluation of myocyte contractility and biochemistry at the sarcomere level before and after LVAD may explain organ-level changes. METHODS AND RESULTS Paired LV tissue samples were frozen from 8 patients with nonischemic cardiomyopathy at LVAD implantation (before LVAD) and before cardiac transplantation (after LVAD). These were compared with 8 nonfailing hearts. Isolated skinned myocytes were purified and attached to a force transducer, and dimensions, maximum calcium-saturated force, calcium sensitivity, and myofilament cooperativity were assessed. Relative isoform abundance and phosphorylation levels of sarcomeric contractile proteins were measured. With LVAD support, the unloaded EF improved (10.0±1.0% to 25.6±11.0%, P=0.007), LV size decreased (LV internal dimension at end diastole, 7.6±1.2 to 4.9±1.4 cm; P<0.001), and myocyte dimensions decreased (cross-sectional area, 1247±346 to 638±254 μm(2); P=0.001). Maximum calcium-saturated force improved after LVAD (3.6±0.9 to 7.3±1.8 mN/mm(2), P<0.001) implantation but was still lower than in nonfailing hearts (7.3±1.8 versus 17.6±1.8 mN/mm(2), P<0.001). An increase in troponin I (TnI) phosphorylation after LVAD implantation was noted, but protein kinase C phosphorylation of TnI decreased. Biochemical changes of other sarcomeric proteins were not observed after LVAD. CONCLUSIONS There is significant improvement in LV and myocyte size with LVAD, but there is only partial recovery of EF and myocyte contractility. LVAD support was associated only with biochemical changes in TnI, suggesting that alternate mechanisms might contribute to contractile changes after LVAD and that additional interventions may be needed to alter biochemical remodeling of the sarcomere to further enhance myofilament and organ-level recovery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incomplete Recovery of Myocyte Contractile Function Despite Improvement of Myocardial Architecture With Left Ventricular Assist Device Support

Sustained recovery of the failing left ventricle (LV) during pressure-volume unloading with an LV assist device (LVAD) is rare and may be related to incomplete recovery of sarcomeric contractility. In this study, the authors evaluated contractility and biochemistry at the most fundamental contractile level of the heart: the sarcomere. Force development in muscle is the result of actin and myosi...

متن کامل

Incomplete Recovery of Myocyte Contractile Function Despite Improvement of Myocardial Architecture With Left Ventricular Assist Device Support Ambardekar et al: Myocyte recovery after LVAD

Background Unloading a failing heart with a left ventricular assist device (LVAD) can improve ejection fraction (EF) and left ventricular (LV) size; however, recovery with LVAD explantation is rare. We hypothesized that evaluation of myocyte contractility and biochemistry at the sarcomere level before and after LVAD may explain organ level changes. Methods and Results Paired LV tissue samples w...

متن کامل

Left ventricular assist device in end-stage heart failure: persistence of structural myocyte damage after unloading. An immunohistochemical analysis of the contractile myofilaments.

OBJECTIVES We sought to evaluate the contractile proteins in cardiomyocytes of patients with end-stage heart failure (HF) before and after mechanical support with a left ventricular assist device (LVAD). BACKGROUND Improvement of myocyte dysfunction has been suggested after LVAD support. METHODS Fourteen patients' myocardial biopsies taken at the time of LVAD implantation and after explanta...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل