Microbiological Seal of Two Types of Tapered Implant Connections.

نویسندگان

  • Wheslley M Peruzetto
  • Elizabeth F Martinez
  • Daiane C Peruzzo
  • Júlio Cesar Joly
  • Marcelo H Napimoga
چکیده

Tapered implant connections have gained wide popularity for being more resistant to fatigue and for promoting a better seal against bacterial infiltration than conventional connections. The aim of this study was to evaluate the bacterial seal at the implant-abutment interface using two Morse taper implant models, by in vitro microbiological analysis. Eleven non-indexed and 11 indexed abutments were selected and connected to their respective implants with a 20 N torque, according to manufacturer's recommendation. Microbiological analysis was carried out using colonies of Escherichia coli transported directly from a culture dish to the prosthetic component. For control, one non-contaminated abutment-implant set from each group (negative control) and one contaminated implant with no abutment (positive control) were used. The specimens were immersed in BHI broth and maintained in an incubator at 37 °C for 14 days to assess the development of bacterial contamination. The results revealed that 36.4% (n=4) of the indexed components and 90.9% (n=10) of the non-indexed components allowed bacterial leakage, with significant difference between groups (p=0.0237). In conclusion, both tapered components failed to provide adequate sealing to bacterial leakage, although the indexed type components showed a superior seal compared with non-indexed components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbiological Sealing Analysis of a Tapered Connection and External Hexagon System

Considering the variety of implant connection systems available in the market and the contrasting literature regarding tapered connection systems in terms of bacterial leakage, the aim of this in vitro study was to compare the effectiveness of the bacterial seal at the implant/abutment interface between an external hexagon and a tapered connection system. Twelve sets of indexed tapered connecti...

متن کامل

مقایسه آزمایشگاهی ریزنشت آپیکالی در روش تراکم جانبی با استفاده از مخروط‌های گوتاپرکای اصلی 02/0 و 04/0

Background and Aim: The final objective of root canal therapy is to create a hermetic seal along the length of the root canal system from the coronal opening to the apical termination and to accomplish the best adaptation of obturation material with canal walls. The purpose of this study was to compare the microleakage during lateral condensation of 0.04 and 0.02 tapered gutta-percha master con...

متن کامل

Comparative response of epithelial cells and osteoblasts to microfabricated tapered pit topographies in vitro and in vivo.

Microfabricated tapered pits in vivo can stimulate connective tissue and bone attachment to percutaneous devices, secondarily preventing epithelial migration, and promoting long-term implant survival. Epithelial cells, which form a seal with a dental implant, acting as a barrier, and osteoblasts, which form bone, can come into contact with the same implant topography. To investigate whether the...

متن کامل

Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.

OBJECTIVE To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. MATERIALS AND METHODS A cross-sectional study was performed involving 40 patients treated with metal-ceramic...

متن کامل

In vitro microbiological analysis of bacterial seal at the implant-abutment interface using two morse taper implant models.

The objective of this study was to evaluate the bacterial seal at the implant-abutment interface using two morse taper implant models, by means of an in vitro microbiological analysis. For that were used 15 implants with mini-abutments tightened by friction, no screws (Group 1); and 30 implants with screw-tightened abutments, of which 15 received 20 N.cm of closing torque (Group 2) and the othe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2016