Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
نویسندگان
چکیده
The aim of the study was to evaluate the mid-term clinical results and survivorship of a rotating-hinge knee prosthesis (LINK® Endo-Model) in difficult primary and complex revision situations. Results after primary implantation were compared with those of revision procedures. Forty-nine prostheses in 45 patients were reviewed clinically during follow up. Twenty-one of these were implanted in primary and 28 in revision situations. Outcome was evaluated using commonly used scores (Knee Society, UCLA Activity, Lequesne) and a visual analog scale after a mean follow up of 56±37 months for 49 prostheses. Implant survival was analyzed using the Kaplan-Meier method. There were no significant differences in clinical examination and evaluation scores between the two groups (P>0.05). Survival rates at final follow up were 95% after primary implantation and 76% in revision procedures. The risk of prosthesis loss (odds ratio 5.7) was significantly higher after revision procedures (P=0.004). These data suggest that rotating-hinge knee prostheses provided good clinical and functional results in selected cases of advanced primary gonarthrosis associated with severe bone loss, ligamentous instability or comminuted fractures. They also provide good results in revision situations. However, the failure rate was significantly higher in cases of revision surgery.
منابع مشابه
Results with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty.
Rotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthr...
متن کاملEarly Results of a New Rotating Hinge Knee Implant
BACKGROUND Indication for rotating hinge (RH) total knee arthroplasty (TKA) includes primary and revision cases, with contradictory results. The aim of this study was to report prospective early results of a new modular rotating hinge TKA (EnduRo). For this implant several new design features and a new bearing material (carbon-fiber reinforced poly-ether-ether-ketone) have been developed. Furth...
متن کاملRotating-hinge total knee for revision total knee arthroplasty.
Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...
متن کاملOutcomes of Varus Valgus Constrained Versus Rotating-Hinge Implants in Total Knee Arthroplasty.
The stability of a total knee arthroplasty is determined by the ability of the prosthesis components in concert with supportive bone and soft tissue structures to sufficiently resist deforming forces transmitted across the knee joint. Constrained prostheses are used in unstable knees due to their ability to resist varus and valgus transformative forces across the knee. Constraint requires inher...
متن کاملEndoprosthetic replacement of the distal femur for bone tumours: long-term results.
We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and 'servicing' procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 ha...
متن کامل