Mastering the IOLMaster 16

نویسنده

  • Sean Henahan
چکیده

WHILE the IOLMaster has become an indispensable tool for pre-operative assessment of cataract patients, it is important to understand its limitations, reported British researchers at the 8th ESCRS Winter Refractive Surgery meeting. “Accurate and precise biometry is one of the key factors in obtaining a good refractive outcome after cataract surgery.An error of only 1.0 mm in axial length will results in a post-operative refractive error of three dioptres,” noted consultant ophthalmologist Andrea Kerr MD. She commented that the advent of the IOLMaster (Humphrey Zeiss), which uses partial coherence interferometry technology, has mostly eliminated operator error, and proven to be a boon for biometric assessment. But she cautioned that the IOLMaster is not accurate in certain eyes, such as those with very dense cataracts. Ultrasound biometry still has an important role to play in this regard. Dr Kerr and colleagues at Northampton General Hospital in England compared the accuracy of measurements obtained with the Storz Compuscan A/B ultrasound biometry instrument and those obtained with the IOL Master. They compared axial length measurements and predicted intraocular lens implant power in 93 eyes of 93 patients undergoing preoperative assessment for cataract surgery. Dr Kerr performed sutureless phacoemulsification, scleral tunnel incision, and in-the-bag IOL placement in all eyes. Patients received the Akreos fit foldable lens (Bausch and Lomb). Emmetropia was the target postoperative refraction in all eyes. The researchers used the Hoffer Q and SRKT formulae to calculate emmetropia according to guidelines established by the Royal College of Ophthalmology.A single examiner performed subjective refractions on all eyes two weeks after surgery. The axial length measurements obtained with the IOLMaster were significantly longer than with the Compuscan technique. Indeed, the IOLMaster axial length measurements were longer than the Compuscan measurements in 98% of cases.The mean deviation in axial lengths obtained by the two systems was 0.637 mm, with a range of deviation between –02.2 mm and +2.14 mm.The differences were highly statistically significant. “The correlation value between the A scan and IOL Master was 0.17.This indicates that there is no linear relationship between the two machines.The mean error in axial length measurements was 0.55 mm. IOL implant power determined by the IOL Master compared to that suggested by the A scan showed a mean difference of +2.4D,” Dr Kerr reported. She noted that there was also a large discrepancy between the machines in terms of the power of the predicted intraocular lens.The difference ranged from –0.5 D to +6.0 D. Subjective refractive measurements obtained post-operatively showed that 55% of the eyes were within 0.5 D of the spherical equivalent predicted by the IOLMaster and 80% were within one dioptre. The current prospective clinical study confirms that the IOLMaster provides longer axial length measurements than the A scan Compuscan machine. Other research groups have reported this previously. In this study, the mean difference between the two axial lengths was 0.637 mm, a larger mean difference in axial length than quoted in previous studies. This might be attributable to refractive instability during the two-week post-operative period in which the measurements were taken. Unlike the IOLMaster,A scan ultrasound biometry is a contact method and is operator dependent. Experience has shown that excessive corneal indentation compresses the eye, in the anterior-toposterior direction.This produces an artificially short eye, producing the kind of myopic refractive results seen in this and earlier studies. “Our study showed that this myopic error could have been as large as 3.68D in some cases, which would have resulted in an entirely unsatisfactory refractive outcome," Dr Kerr said. She stressed that the inability to standardise corneal indentation is a major failing with applanation ultrasound biometry.The error associated with corneal indentation in applanation biometry is not predictable, as it depends in large part on the experience of the operator. “Despite these failings, the contact method still has a place in current ophthalmic practice.The IOLMaster is unable to determine axial length in up to ten percent of cataract patients.This could include patients with dense cataracts or corneal opacification. In addition, patients with age-related macular degeneration or mental handicap might be unable to fixate, making them candidates for the A scan method.” The IOLMaster can measure axial length, corneal radii and anterior-chamber depth. The onboard software incorporates all operating processes from the measurement of the parameters to the computation of the IOL through the integrated biometric formulas and lens database. Because it is a non-contact technique local anaesthesia is not required and there and no risk of infection. Dr Kerr told EuroTimes that in her clinic the A-scan still had an important place, noting that several of her senior nursing staff had gained considerable expertise with the ultrasound technique. She noted that it was useful as a comparative tool for measuring the accuracy and consistency of the IOL master. It is also useful in difficult cases where the IOLMaster does not give a result and in difficult and uncooperative patients. Dr Kerr emphasised the value of using computer database programmes for storing all pre-operative and post-operative biometry data.This greatly assists statistical analysis. Over time, and with regular audit of post-operative refraction results, a nomogram can be obtained for each nurse/technician’s A-scan results, which allow the correct lens to be chosen if the IOL Master cannot be used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the accuracy of the ORange® (Gen II) by comparing it to the IOLMaster® in the prediction of postoperative refraction

PURPOSE The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). SETTING The Surgical Suites, Honolulu, HI. METHODS The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalen...

متن کامل

Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...

متن کامل

A comparison of Scheimpflug imaging simulated and Holladay equivalent keratometry values with partial coherence interferometry keratometry measurements in phakic eyes.

OBJECTIVE To evaluate the interchangeability of a Scheimpflug camera (Pentacam, Oculus) and a partial coherence interferometry keratometer (IOLMaster, Zeiss) for measures of keratometry and anterior chamber depth (ACD). A particular focus was to determine which Pentacam keratometry value best correlates with the IOLMaster and if these results can be used interchangeably in clinical practice. ...

متن کامل

Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster.

PURPOSE To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115 patients using Orbscan II and IOLMaster. Average patient age was 52.9+/-19.4 (range 16 to 87) year...

متن کامل

Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500

PURPOSE To compare the measurements and failure rates obtained with a new swept source optical coherence tomography (OCT)-based biometry to IOLMaster 500. SETTING Eye Clinic, Baskent University Faculty of Medicine, Ankara, Turkey. DESIGN Observational cross-sectional study and evaluation of a new diagnostic technology. METHODS 188 eyes of 101 subjects were included in the study. Measureme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004