Global Patch Matching (GPM) for freehand 3D ultrasound reconstruction

نویسندگان

  • Weijian Cong
  • Jian Yang
  • Danni Ai
  • Hong Song
  • Gang Chen
  • Xiaohui Liang
  • Ping Liang
  • Yongtian Wang
چکیده

BACKGROUND 3D ultrasound volume reconstruction from B-model ultrasound slices can provide more clearly and intuitive structure of tissue and lesion for the clinician. METHODS This paper proposes a novel Global Path Matching method for the 3D reconstruction of freehand ultrasound images. The proposed method composes of two main steps: bin-filling scheme and hole-filling strategy. For the bin-filling scheme, this study introduces two operators, including the median absolute deviation and the inter-quartile range absolute deviation, to calculate the invariant features of each voxel in the 3D ultrasound volume. And the best contribution range for each voxel is obtained by calculating the Euclidian distance between current voxel and the voxel with the minimum invariant features. Hence, the intensity of the filling vacant voxel can be obtained by weighted combination of the intensity distribution of pixels in the best contribution range. For the hole-filling strategy, three conditions, including the confidence term, the data term and the gradient term, are designed to calculate the weighting coefficient of the matching patch of the vacant voxel. While the matching patch is obtained by finding patches with the best similarity measure that defined by the three conditions in the whole 3D volume data. RESULTS Compared with VNN, PNN, DW, FMM, BI and KR methods, the proposed Global Path Matching method can restore the 3D ultrasound volume with minimum difference. CONCLUSIONS Experimental results on phantom and clinical data sets demonstrate the effectiveness and robustness of the proposed method for the reconstruction of ultrasound volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Reconstruction from Sparse & Arbitrarily Oriented Contours in Freehand 3D Ultrasound

3D reconstruction for freehand 3D ultrasound is a challenging issue because the recorded B-scans are not only sparse, but also non-parallel (actually they may arbitrarily orient in 3D space and may intersect each other). Conventional volume reconstruction methods can’t reconstruct sparse data efficiently while not introducing geometrical artifacts and conventional surface reconstruction methods...

متن کامل

Reconstruction of freehand 3D ultrasound based on kernel regression

INTRODUCTION Freehand three-dimensional (3D) ultrasound has the advantages of flexibility for allowing clinicians to manipulate the ultrasound probe over the examined body surface with less constraint in comparison with other scanning protocols. Thus it is widely used in clinical diagnose and image-guided surgery. However, as the data scanning of freehand-style is subjective, the collected B-sc...

متن کامل

Backward-Warping Ultrasound Reconstruction for Improving Diagnostic Value and Registration

Freehand 3D ultrasound systems acquire sets of B-Mode ultrasound images tagged with position information obtained by a tracking device. For both further processing and clinical use of these ultrasound slice images scattered in space, it is often required to reconstruct them into 3D-rectilinear grid arrays. We propose new efficient methods for this so-called ultrasound spatial compounding using ...

متن کامل

Sensorless reconstruction of unconstrained freehand 3D ultrasound data.

Freehand 3D ultrasound can be acquired without a position sensor by finding the separations of pairs of frames using information in the images themselves. Previous work has not considered how to reconstruct entirely freehand data, which can exhibit irregularly spaced frames, intersecting frames, nonmonotonic out-of-plane probe motion and significant in-plane motion. This paper presents reconstr...

متن کامل

Volume Reconstruction from Sparse 3D Ultrasonography

3D freehand ultrasound has extensive application for organ volume measurement and has been shown to have better reproducibility than estimates of volume made from 2D measurement followed by interpolation to 3D. One key advantage of free-hand ultrasound is that of image compounding, but this advantage is lost in many automated reconstruction systems. A novel method is presented for the automated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017