Design of a mouse restraint for synchrotron-based computed tomography imaging.

نویسندگان

  • Kenneth B Gagnon
  • Sally Caine
  • Nazanin Samadi
  • Mercedes Martinson
  • Melanie van der Loop
  • Jane Alcorn
  • L Dean Chapman
  • George Belev
  • Helen Nichol
چکیده

High-resolution computed tomography (CT) imaging of a live animal within a lead-lined synchrotron light hutch presents several unique challenges. In order to confirm that the animal is under a stable plane of anaesthesia, several physiological parameters (e.g. heart rate, arterial oxygen saturation, core body temperature and respiratory rate) must be remotely monitored from outside the imaging hutch. In addition, to properly scan the thoracic region using CT, the animal needs to be held in a vertical position perpendicular to the fixed angle of the X-ray beam and free to rotate 180°-360°. A new X-ray transparent mouse restraint designed and fabricated using computer-aided design software and three-dimensional rapid prototype printing has been successfully tested at the Biomedical Imaging and Therapy bending-magnet (BMIT-BM) beamline at the Canadian Light Source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2015