Advanced Procedure for Fabrication of Substructure in Dentistry

نویسندگان

  • B. TRIFKOVIĆ
  • M. POTRAN
  • T. BRAJLIH
چکیده

I. Matin, M. Hadžistević, Đ. Vukelić, I, Faculty of Technical Sciences, University of Novi Sad, Serbia. B. Trifković, Clinic for Prosthodontics, School for Dentistry, University of Belgrade, Serbia, M. Potran, Medical Faculty, University of Novi Sad, Serbia, T. Brajlih, I. Drstvenšek, Faculty of Mechanical Engineering, University of Maribor, Slovenia. The paper presents some aspects of the novel integrated system, procedure for fabrication of metal substructure of metal-ceramic crowns. The results been shown that the CAD/CAE/RP technology integration presented in this paper can be fully applied to casting metal substructures. The substructure fabricated in this way, confirm the reduction of the total manufacturing time, with an increase in the percentage of high quality castings that use integrated system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro and In vivo Investigation of poly(lactic acid)/hydroxyapatite nanoparticle scaffold containing nandrolone decanoate for the regeneration of critical-sized bone defects

Objective(s): Bone tissue engineering is aimed at the fabrication of bone graft to ameliorate bone defects without using autografts or allografts. Materials and Methods: In the present study, the coprecipitation method was used to prepare hydroxyapatite (HA) nanoparticles containing nandrolone. To do so, 12.5, 25, and 50 mg of nandrolone were loaded into poly(lactic acid) (PLA)/nano-HA, a...

متن کامل

The Effect of Full Crown Preparation on Normal and Inflamed Pulp Tissue: An Animal Study

Introduction: Full crown preparation may have adverse effects on pulp tissue. In this study, the effect of full-crown preparation on intact versus inflamed pulp tissue was studied. Methods: Fifteen healthy mature cats were randomly selected for this study. The study was performed on four canine teeth of each cat. Cats were anesthetized and then radiographs were taken from the canine teeth. Clas...

متن کامل

Rehabilitation of a patient with Screw-Retained Metal-Resin Implant-Tissue Supported Fixed Mandibular Complete Denture: A Hybrid Prosthesis (FP – 3): A Case Report

A hybrid denture is one that is fabricated over a metal framework and retained by screws threaded into the implants. The anterior part of a mandibular hybrid denture is fixed on implants while the posterior part of the denture is extended and cantilevered from implants. This article presents the fabrication of a mandibular implant retained hybrid prosthesis. A total of four implants were placed...

متن کامل

Desiging, Part Selecting and Fabrication Procedure of the Vaccum Section of a Leaf Vacuum Shredder Machine

Due to the massive loss of leaves in parks and green spaces and big cities such as Isfahan and the lack of domestic production of leaf vacuum shredder machine for use in large green spaces of parks, the design and construction of the collecting and recycling by the system is need so the design of the vaccum section which is one of the main parts and includes entrance, channels and ducts and exh...

متن کامل

Desiging, Part Selecting and Fabrication Procedure of the Vaccum Section of a Leaf Vacuum Shredder Machine

Due to the massive loss of leaves in parks and green spaces and big cities such as Isfahan and the lack of domestic production of leaf vacuum shredder machine for use in large green spaces of parks, the design and construction of the collecting and recycling by the system is need so the design of the vaccum section which is one of the main parts and includes entrance, channels and ducts and exh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016