Gas flow analysis of puffer-type circuit breaker using FGCBM method

نویسندگان

  • Seong-Kwan Park
  • Jun Choe
چکیده

This paper presents the flow field analysis in the Puffer-tyep (P-T) circuit breakers. There are many problems in analyzing the flow field in circuit breakers such as shock wave, complex geometry, moving boundary and so on. For the cold gas analysis, the flow field computation for the high voltage gas blast circuit breaker with the moving boundary by meshfree (FGCBM) method[1,2] is employed to solve the Euler equation. The piston and the electric contact are moving. Since the boundary moving, is is difficult for the ordinary finite difference (FD) method or the finite element (FE) method to compute the solution. For the purpose of numerical simplicity and efficiency, we introduced the FGCBM scheme which is an excellent scheme for the time varying domain, Despite the low coding and computational cost, the numerical simulation is successfully conducted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density a...

متن کامل

Failure Mode and Effects Analysis Using Generalized Mixture Operators

Failure mode and effects analysis (FMEA) is a method based on teamwork to identify potential failures and problems in a system, design, process and service in order to remove them. The important part of this method is determining the risk priorities of failure modes using the risk priority number (RPN). However, this traditional RPN method has several shortcomings. Therefore, in this paper we p...

متن کامل

An Innovative System for Full-Management of CB Using Current Injection Method

In this article, an innovative supervision system will be proposed that can observe and analyze health of Circuit Breaker’s trip coil. The proposed design also logs changes in the coil's quality and informs network supervisor in case of Circuit Breaker (CB) failure. This system injects small direct currents to the Circuit Breaker connections and the trip coil to compute CB’s health and characte...

متن کامل

Analysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure

Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...

متن کامل

Fault location and classification in non-homogeneous transmission line utilizing breaker transients

In this paper, a single-ended fault location method is presented based on a circuit breaker operation using the frequencies of traveling waves. The proposed method receives the required data from voltage traveling waves with the aid of Fast Fourier Transform (FFT) and Wavelet Transform. Then, the Artificial Neural Network (ANN) identifies fault type and determines its location. In order to eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008