Validation of Legionella pneumophila indirect immunofluorescence assay with epidemic sera.

نویسندگان

  • H W Wilkinson
  • D D Cruce
  • C V Broome
چکیده

Sera from six outbreaks of legionellosis and four outbreaks of pneumonia of other etiologies were tested with the indirect immunofluorescence assay (IFA) as currently performed. The current IFA is at least as sensitive as the original test in detecting cases of Legionnaires disease (78 to 91%). By using Center for Disease Control criteria for a positive (fourfold increase in titer during convalescence to greater than or equal to 128) or presumptive (single titer greater than or equal to 256) serological test, the specificity exceeded 99%. No cross-reactions against Legionella pneumophila antigens were observed among sera from epidemic cases of Q fever, tularemia, and psittacosis; the only positive L. pneumophila IFA titer among the epidemic Mycoplasma pneumonia sera was reduced to a negative titer with an immunosorbent extracted from Escherichia coli strain O13:K92:H4. The slight increase in specificity (to 100%), however, was offset by a slight decrease in sensitivity. The sensitivity of the IFA was maximal when a conjugate that detected immunoglobulins G, M, and A was used. IFA titers were not significantly altered by replacing the monovalent serogroup 1 antigen with a polyvalent antigen (serogroups 1 through 4) nor by the presence of rheumatoid factor or heat-labile serum factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Formalin-killed versus heat-killed Legionella pneumophila serogroup 1 antigen in the indirect immunofluorescence assay for legionellosis.

Indirect immunofluorescence assay titers of human sera obtained against the Legionella pneumophila serogroup 1 antigen (Philadelphia 1 strain) killed with 10% Formalin showed a tendency to be lower than those obtained against the reference heat-killed antigen (geometric mean titer of 194 and 370, respectively) when all other variables in the test were held constant. Test results were interprete...

متن کامل

Indirect immunofluorescence antibodies to Legionella pneumophila: frequency in a rural community.

The background prevalence of indirect immunofluorescence antibody to Legionella pneumophila in a rural community was determined by testing sera from 517 volunteers. The upper limit of normal antibody titer was found to be 1:64 with L. pneumophila serogroup 1 (Philadelphia 1) used as antigen. High titers (greater than or equal to 1:128) were found in 13.2% of the sera and occurred with similar f...

متن کامل

Detection of antibodies against Legionella pneumophila serogroups 1 to 6 and the Leiden-1 strain by micro ELISA and immunofluorescence assay.

One hundred and seventy-five human sera were tested for the presence of type-specific antibodies against L pneumophila serogroups 1 to 6 and the Leiden-1 strain by means of an enzyme linked immunosorbent assay (ELISA) and compared with the results obtained by the indirect immunofluorescence assay (IFA). A high correlation (correlation coefficient 0.92) between both methods was found. No consist...

متن کامل

Comparison of phenol- and heat-killed antigens in the indirect immunofluorescence test for serodiagnosis of Legionella pneumophila group 1 infections.

An antigen prepared with agar-grown Legionella pneumophila group 1 killed by 0.5% phenol and suspended in 0.5% yolk sac was examined for use in the indirect immunofluorescence test for legionellosis and compared with a heat-killed antigen. The serological results of the two antigens for single and paired sera agreed well. Morphological and staining characteristics were better for phenol-treated...

متن کامل

A rapid microagglutination test for the diagnosis of Legionella pneumophila (serogroup 1) infection.

A rapid microagglutination test has been developed which can be performed in 30 minutes. Ninety-seven percent of 96 patients diagnosed as having Legionella pneumophila (serogroup 1) infection by indirect immunofluorescence were also detected by the rapid microagglutination test.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 1981