Magnitude and directional measures of water and Cr(VI) fluxes by passive flux meter.

نویسندگان

  • Timothy J Campbell
  • Kirk Hatfield
  • Harald Klammler
  • Michael D Annable
  • P S C Rao
چکیده

A new configuration of the passive fluxmeter (PFM) is presented that provides for simultaneous measurements of both the magnitude and the direction of ambient groundwater specific discharge qo and Cr(VI) mass flux J(Cr). The PFM is configured as a cylindrical unit with an interior divided into a center section and three outer sectors, each packed with a granular anion exchange resin having high sorption capacity for the Cr(VI) oxyanions CrO4(2-) and HCrO4-. The sorbent in the center section is preloaded with benzoate as the "resident" tracer. Laboratory experiments were conducted in which PFMs were placed in porous packed bed columns, through which was passed a measured volume of synthetic groundwater containing Cr(VI). During the deployment period, some of the resident tracer is depleted while the Cr(VI) is sorbed. The resin was then removed from the four sectors separately and extracted to determine the "captured" mass of Cr(VI) and the residual mass of the resident tracer in each. Cumulative specific discharge, q0t, values were assessed using the residual mass of benzoate retained in the center section. The direction of this discharge theta was ascertained from the mass distribution of benzoate intercepted and retained in the outer three sections of the PFM. Cumulative chromium fluxes, J(Cr)t, were quantified using the total Cr(VI) mass intercepted and retained on the PFM. Experiments produced an average measurement error for direction theta of 3 degrees +/- 14 degrees, while the average measurement errors for q0 and J(Cr) were, respectively, -8% +/- 15% and -12% +/- 23%. Results demonstrate the potential utility of the new PFM configuration for characterizing groundwater and contaminant fluxes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A direct passive method for measuring water and contaminant fluxes in porous media.

This paper introduces a new direct method for measuring water and contaminant fluxes in porous media. The method uses a passive flux meter (PFM), which is essentially a self-contained permeable unit properly sized to fit tightly in a screened well or boring. The meter is designed to accommodate a mixed medium of hydrophobic and/or hydrophilic permeable sorbents, which retain dissolved organic/i...

متن کامل

Contaminant discharge and uncertainty estimates from passive flux meter measurements

[1] The passive flux meter (PFM) measures local cumulative water and contaminant fluxes at an observation well. Conditional stochastic simulation accounting for both spatial correlation and data skewness is introduced to interpret passive flux meter observations in terms of probability distributions of discharges across control planes (transects) of wells. An estimator of the effective number o...

متن کامل

Characterization of tannery effluents of Hazaribagh area, Dhaka, Bangladesh

The present investigation characterizes tannery effluents by determining water quality parameters and some selected trace metallic constituents in order to measure the magnitude of environmental pollution. Effluents and sediments have also been used to isolate chromium-resistant bacteria, collected from Hazaribagh area, Dhaka, claimed to be increasing Cr (VI)-enriched environments, and utilized...

متن کامل

Characterization of tannery effluents of Hazaribagh area, Dhaka, Bangladesh

The present investigation characterizes tannery effluents by determining water quality parameters and some selected trace metallic constituents in order to measure the magnitude of environmental pollution. Effluents and sediments have also been used to isolate chromium-resistant bacteria, collected from Hazaribagh area, Dhaka, claimed to be increasing Cr (VI)-enriched environments, and utilized...

متن کامل

Field-scale evaluation of the passive flux meter for simultaneous measurement of groundwater and contaminant fluxes.

A new method, passive flux meter (PFM), has been developed and field-tested for simultaneously measuring contaminant and groundwater fluxes in the saturated zone at hazardous waste sites. The PFM approach uses a sorptive permeable medium placed in either a borehole or monitoring well to intercept contaminated groundwater and release "resident" tracers. The sorbent pack is placed in a groundwate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 40 20  شماره 

صفحات  -

تاریخ انتشار 2006