The effect of hip resurfacing on oxygen concentration in the femoral head.

نویسندگان

  • R T Steffen
  • S R Smith
  • J P G Urban
  • P McLardy-Smith
  • D J Beard
  • H S Gill
  • D W Murray
چکیده

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The anterolateral approach leads to less disruption of the femoral head-neck blood supply than the posterior approach during hip resurfacing.

In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure...

متن کامل

The Effect of Femoral Neck Notching with the Birmingham Mid-Head Resection

The new generation of metal-on-metal hip resurfacing is becoming an increasingly popular alternative to total hip replacement in the younger and more active patient. Mid-term survivorship figures for osteoarthritic patients are comparable to that of patients receiving a total hip arthroplasty. However, individuals receiving a hip resurfacing for aetiologies other than OA, such as avascular necr...

متن کامل

The Vascular Evaluation of Femoral Head Remnant after Resurfacing Hip Arthroplasty

RESURFACING HIP ARTHROPLASTY +*Hananouchi, T; *Sugano, N; *Nishii, T; *Sakai, T; **Miki, H;**Lee, SB; **Ohzono, K; *Yoshikawa, H +*Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine [email protected] Introduction: Metal on metal resurfacing hip arthroplasty (RHA) has been getting popularity due to its concept of bone conservation, stability, and expected longevi...

متن کامل

Femoral head blood flow during hip resurfacing.

Preserving femoral head vascularity during hip resurfacing may avoid femoral neck fractures and late femoral loosening. The posterior approach and notching of the femoral neck influence femoral head perfusion. However, it is not known if standard preparation of the femoral head during hip resurfacing can disrupt blood flow. Ten patients (10 hips) with advanced osteoarthritis having metal-on-met...

متن کامل

A comparison of leg length and femoral offset discrepancies in hip resurfacing, large head metal-on- metal and conventional total hip replacement: a case series

BACKGROUND A discrepancy in leg length and femoral offset restoration is the leading cause of patient dissatisfaction in hip replacement surgery and has profound implications on patient quality of life. The aim of this study is to compare biomechanical hip reconstruction in hip resurfacing, large-diameter femoral head hip arthroplasty and conventional total hip replacement. METHOD Sixty patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 87 11  شماره 

صفحات  -

تاریخ انتشار 2005