Quantification of regional myocardial perfusion with generator-produced 62Cu-PTSM and positron emission tomography.

نویسندگان

  • P Herrero
  • J Markham
  • C J Weinheimer
  • C J Anderson
  • M J Welch
  • M A Green
  • S R Bergmann
چکیده

BACKGROUND Noninvasive assessment of regional myocardial perfusion at rest and after stress is important for the objective evaluation of the effects of coronary artery disease and its response to therapy. Centers that do not have cyclotrons rely on generator-produced radioisotopes for assessment of regional myocardial perfusion with positron emission tomography (PET). The aim of the present study was to develop and implement an approach to quantify regional myocardial perfusion using copper(II) pyruvaldehyde bis-(N4-thiosemicarbazone) (PTSM) labeled with the generator-produced, positron-emitting radionuclide 62Cu (t1/2 = 9.7 minutes). METHODS AND RESULTS Regional perfusion was estimated from dynamic PET scans after intravenous administration of 62Cu-PTSM in 21 studies in 13 intact dogs evaluated over a wide range of myocardial flow values. In 15 interventions in nine dogs, regional perfusion was also estimated with H2(15)O. Regional perfusion with 62Cu-PTSM was estimated from dynamic blood and tissue time-activity curves, along with the model parameter k1 (forward rate of transport) and the PET parameter FBM (fraction of blood pool activity observed in tissue), using a two-compartment kinetic model. Arterial blood activity was corrected for red blood cell-associated 62Cu. In 44 comparisons, estimates of regional perfusion with 62Cu-PTSM correlated well with estimates obtained with concomitantly administered radiolabeled microspheres (y = 0.90x +/- 0.15, r = 0.95, p < 0.05) over a flow range from 0.23 to 6.14 ml/g per minute. In five healthy human volunteers evaluated at rest with H2(15)O and 62Cu-PTSM, regional perfusion estimated with 62Cu-PTSM was not significantly different from that obtained with H2(15)O (1.05 +/- 0.36 versus 0.96 +/- 0.28 ml/g per minute). 62Cu-PTSM provided high-quality images of the heart. CONCLUSIONS The results of this study demonstrate that quantification of regional myocardial perfusion is feasible using generator-produced 62Cu-PTSM. Since 62Cu-PTSM can be used to estimate perfusion in the brain, kidney, and tumors as well as in the heart, it is an attractive tracer for centers that rely on generator-produced tracers for the evaluation of perfusion with PET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of regional myocardial and renal blood flow with copper-PTSM and positron emission tomography.

We recently demonstrated in isolated, perfused hearts that radiolabeled pyruvaldehyde bis(N4-methylthiosemicarbazonato)copper(II) (Cu-PTSM) is well extracted throughout a range of conditions including ischemia, hypoxia, and hyperemia. Once extracted, binding of radioactivity by the isolated heart was essentially irreversible, giving this tracer microspherelike qualities. Because Cu-PTSM can be ...

متن کامل

Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography.

Positron emission tomography offers the ability to noninvasively assess regional myocardial perfusion in absolute terms (i.e., milliliters per gram per minute). Accurate estimates have been difficult to achieve with generator-produced 82Rb because of the complex behavior of this tracer in the myocardium. The aim of the present study was to determine whether regional myocardial blood flow could ...

متن کامل

Assessment of Regional Myocardial and Renal Blood Flow With CoppermPTSM and Positron Emission Tomography

We recently demonstrated in isolated, perfused hearts that radiolabeled pyruvaldehyde bis(N4-methylthiosemicarbazonato)copper(II) (Cu-PTSM) is well extracted throughout a range of conditions including ischemia, hypoxia, and hyperemia. Once extracted, binding of radioactivity by the isolated heart was essentially irreversible, giving this tracer microspherelike qualities. Because Cu-PTSM can be ...

متن کامل

Noninvasive Quantification of Regional Myocardial Perfusion With Rubidium-82 and Positron Emission Tomography

Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...

متن کامل

Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model.

Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 1993