Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve
نویسندگان
چکیده
BACKGROUND Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, have all to be accounted for when assessing the device functionality. Even though all these issues have been and continue to be widely investigated, they are not usually studied through an integrated approach yet, i.e. by analyzing them simultaneously and highlighting their connections. RESULTS An in vitro test campaign of flow through a bileaflet mechanical heart valve (Sorin Slimline 25 mm) was performed in a suitably arranged pulsatile mock loop able to reproduce human systemic pressure and flow curves. The valve was placed in an elastic, transparent, and anatomically accurate model of healthy aorta, and tested under several pulsatile flow conditions. Global and local hydrodynamics measurements and leaflet dynamics were analysed focusing on correlations between flow characteristics and valve motion. The haemolysis index due to the valve was estimated according to a literature power law model and related to hydrodynamic conditions, and a correlation between the spatial distribution of experimental shear stress and pannus/thrombotic deposits on mechanical valves was suggested. As main and general result, this study validates the potential of the integrated strategy for performance assessment of any prosthetic valve thanks to its capability of highlighting the complex interaction between the different physical mechanisms that govern transvalvular haemodynamics. CONCLUSIONS We have defined an in vitro procedure for a comprehensive analysis of aortic valve prosthesis performance; the rationale for this study was the belief that a proper and overall characterization of the device should be based on the simultaneous measurement of all different quantities of interest for haemodynamic performance and the analysis of their mutual interactions.
منابع مشابه
Intermediate-term results after the aortic valve replacement using bileaflet mechanical prosthetic valve in children.
OBJECTIVE Intermediate/long-term results after aortic valve replacement using bileaflet mechanical valve in children should be clarified as a standard of treatment of aortic valve disease in children. METHODS Forty-five patients aged under 15 years underwent 46 aortic valve replacements using bileaflet mechanical prosthetic valve. Patients' ages ranged from 1 to 15 years (9 years as a median ...
متن کاملProspectively randomized comparison of different mechanical aortic valves.
BACKGROUND The aim of this prospectively randomized study was to evaluate the hemodynamic and functional outcomes after aortic valve replacement with 3 different bileaflet mechanical valves. METHODS AND RESULTS Three hundred consecutive patients were randomly assigned to receive ATS (n=100), Carbomedics (n=100), or St Jude Medical Hemodynamic Plus (n=100) mechanical aortic valve replacement. ...
متن کاملThe Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
BACKGROUND AND OBJECTIVES The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS In 20 patients (mean age, 50+/-12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical...
متن کاملAn integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flo...
متن کاملAccuracy of Doppler-echocardiographic parameters for the detection of aortic bileaflet mechanical prosthetic valve dysfunction.
AIMS In vitro and in vivo studies were performed to evaluate the diagnostic accuracy of the different Doppler-echocardiographic parameters proposed in the American Society of Echocardiography guidelines to identify dysfunction of bileaflet mechanical valves (BMV) in the aortic position. METHODS AND RESULTS Two models of BMV (St Jude HP, MCRI On-X) of different sizes (21;23;25;27 mm) were test...
متن کامل