Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women

نویسندگان

  • Rahele Alijahan
  • Masoumeh Kordi
  • Munira Poorjavad
  • Saeed Ebrahimzadeh
چکیده

BACKGROUND Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. MATERIALS AND METHODS This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). RESULTS Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. CONCLUSIONS Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors of Dystocia in Nulliparous Women

Background: Detection of women at risk for dystocia will allow physicians to make preparations and treatment decisions that can minimize maternal and neonatal morbidity. We aimed to determine the risk factors for dystocia in nulliparous women. Methods: This case series enrolled 447 nulliparous women who presented with a single pregnancy in the vertex presentation and gestational age of 38-42 we...

متن کامل

ارزش تشخیصی قطر عرضی میکائیل ساکرال در تلفیق با قد زنان نخست‌زا در پیشگویی زایمان سخت

Background and Aim: Detection of women at risk of dystocia could minimize the maternal and neonatal morbidity. The objective of our study was to determine The diagnostic accuracy of the combination of maternal height and transvers diagonal of Michaelis sacral rhomboid to predict dystocia in nulliparous women who referred to Ommolbanin Hospital of Mashade between December 2008 and June 2009. Mat...

متن کامل

Risk Factors of Dystocia in Nulliparous Women

BACKGROUND Detection of women at risk for dystocia will allow physicians to make preparations and treatment decisions that can minimize maternal and neonatal morbidity. We aimed to determine the risk factors for dystocia in nulliparous women. METHODS This case series enrolled 447 nulliparous women who presented with a single pregnancy in the vertex presentation and gestational age of 38-42 we...

متن کامل

مقایسه ارزش تشخیصی پلویمتری بالینی و اندازه‌گیری خارجی اقطار لگنی زنان نخست‌زا در پیشگویی زایمان سخت

Introduction: Clinical pelvimetry is very uncomfortable for the patient and is associated with subjective error, while external pelvimetry is a simple and acceptable method for patients. The objective of this study was to compare the diagnostic accuracy of clinical and external pelvimetry in prediction of dystocia in nulliparous women. Methods: In this study between December 2008 and January 2...

متن کامل

Magnetic resonance imaging pelvimetry and the prediction of labor dystocia.

OBJECTIVE To study whether magnetic resonance imaging (MRI) pelvimetry has the ability to identify those women who require cesarean delivery for labor dystocia. METHODS From July 2003 to April 2004, nulliparous women scheduled for a labor induction for prolonged pregnancy (42 weeks) were asked to participate in a pelvimetry study. Those who consented underwent fast-acquisition MRI that includ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2014