Transconjunctival sutureless 25-gauge vitrectomy with newly designed microcannulas.

نویسنده

  • Takeshi Naito
چکیده

AIM To evaluate the usefulness of the newly designed 25-gauge (25-G) microcannula for transconjunctival sutureless vitrectomy (TSV). METHODS 25-G TSV was performed on 20 consecutive eyes with the newly designed 25-G microcannulas. We studied usefulness, intraoperative and postoperative complications in these cases. RESULTS No complications were recognized during surgery. Postoperative complications included blebs in five eyes, vitreous hemorrhage in one eye, high intraocular pressure (more than 22 mmHg) in one eye and a retinal tear in one eye. No eyes with low intraocular pressure (less than 10 mmHg) were noted. CONCLUSIONS This microcannula for 25-G vitrectomy is thought to be very useful and effective for performing 25-G vitrectomy safely.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally Invasive Vitreoretinal Surgery

Pars plana vitrectomy (PPV) was introduced almost 40 years ago. 1 In the 1980s and 1990s, three-port PPV with 20-gauge (G) instruments was the norm. In 2002, 25-gauge transconjunctival sutureless vitrectomy (TSV) was introduced.2,3 This system permits threeport PPV using microcannulas, trocars, and 25-G instrumentation without requiring sutures to close the sclerotomies. Subsequently, a similar...

متن کامل

Intraoperative Switch to a Temporal Surgical Approach in 23- and 25-Gauge Microcannula-Based Sutureless Transconjunctival Vitrectomy

PURPOSE To illustrate a surgical method in which the infusion port during a three-port pars plana vitrectomy is moved intraoperatively from the traditional infra-temporal location and placed supra-nasally, thus permitting a temporal surgical approach to better tackle superior and inferior vitreoretinal pathology. METHODS Description of surgical technique. RESULTS When the location of the vi...

متن کامل

Bacterial endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy

PURPOSE To report a case of endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy. DESIGN Observational case report. METHODS An 87-year-old male who underwent sutureless 25-gauge vitrectomy developed unilateral endophthalmitis. Vitreous culture revealed Staphylococcus coagulase-negative bacteria. He was subsequently treated with intravitreal antibiotics and oral prednis...

متن کامل

Advances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy

Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...

متن کامل

Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

BACKGROUND The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of medical investigation : JMI

دوره 55 1-2  شماره 

صفحات  -

تاریخ انتشار 2008