Correlation between quantified breast densities from digital mammography and 18F-FDG PET uptake.

نویسندگان

  • Paras Lakhani
  • Andrew D A Maidment
  • Susan P Weinstein
  • Justin W Kung
  • Abass Alavi
چکیده

To correlate breast density quantified from digital mammograms with mean and maximum standardized uptake values (SUVs) from positron emission tomography (PET). This was a prospective study that included 56 women with a history of suspicion of breast cancer (mean age 49.2 +/- 9.3 years), who underwent 18F-fluoro-2-deoxyglucose (FDG)-PET imaging of their breasts as well as digital mammography. A computer thresholding algorithm was applied to the contralateral nonmalignant breasts to quantitatively estimate the breast density on digital mammograms. The breasts were also classified into one of four Breast Imaging Reporting and Data System categories for density. Comparisons between SUV and breast density were made using linear regression and the Student's t-test. Linear regression of mean SUV versus average breast density showed a positive relationship with a Pearson's correlation coefficient of R(2) = 0.83. The quantified breast densities and mean SUVs were significantly greater for mammographically dense than nondense breasts (p < 0.0001 for both). The average quantified densities and mean SUVs of the breasts were significantly greater for premenopausal than postmenopausal patients (p < 0.05). 8/51 (16%) of the patients had maximum SUVs that equaled 1.6 or greater. There is a positive linear correlation between quantified breast density on digital mammography and FDG uptake on PET. Menopausal status affects the metabolic activity of normal breast tissue, resulting in higher SUVs in pre- versus postmenopausal patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rare case of adenoid cystic carcinoma of the breast detected by (18)F-FDG PET/CT.

A 51-year-old female patient underwent 18F-FDG PET/CT searching for the cause of a fever of unknown origin. Before 18F-FDG injection, the patient had fasted for at least 6 h; at the time of the radiopharmaceutical injection the glucose blood levels corresponded to 96 mg/dL. Images were acquired 1 h after i.v. injection of 280 MBq of 18F-FDG. 18F-FDG PET/CT showed an area of increased radiopharm...

متن کامل

18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value

Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...

متن کامل

Diffuse Intense 18F-FDG Uptake at PET in Unilateral Breast Related to Breastfeeding Practice

We present an interesting case of incidental diffuse fluorodeoxyglucose (FDG) uptake at PET in her left breast, related to atypical breastfeeding practice. Clinically, differential diagnoses of diffuse intense FDG uptake in unilateral breast include advanced breast cancer, breast lymphoma and inflammatory condition. However, normal physiologic lactation may also show increased FDG uptake in the...

متن کامل

Breast cancer staging in a single session: whole-body PET/CT mammography.

UNLABELLED Our objective was to compare the diagnostic accuracy of an all-in-one protocol of whole-body 18F-FDG PET/CT and integrated 18F-FDG PET/CT mammography with the diagnostic accuracy of a multimodality algorithm for initial breast cancer staging. METHODS Forty women (mean age, 58.3 y; range, 30.8-78.4 y; SD, 12 y) with suspected breast cancer were included. For the primary tumor, we co...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The breast journal

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2009