Treatment of AO/OTA 31-A3 intertrochanteric femoral fractures with a percutaneous compression plate
نویسندگان
چکیده
OBJECTIVE AO/OTA 31-A3 intertrochanteric femoral fractures have completely different fracture line directions and biomechanical characteristics compared with other types of intertrochanteric fractures. The choice of the fixation method has been a focus of dispute among orthopedic trauma surgeons. The purpose of this study was to review the outcomes of these fractures treated with a percutaneous compression plate at our institute. METHOD Seventeen patients with AO/OTA 31-A3 intertrochanteric femoral fractures were treated with a percutaneous compression plate at our institute from January 2010 to December 2011. The clinical data and imaging results were retrospectively analyzed. RESULTS The medical complication of popliteal vein thrombosis occurred in one patient. Sixteen patients were followed up for 12 to 21 months. Two patients had malunion and mild pain. Fracture collapse occurred in two patients, with one having head penetration. These two patients had moderate pain. There were no occurrences of nonunion or reoperation. The mean Harris hip score obtained during the last follow-up was 84.1 (61-97). Patients with a poor quality of reduction were more likely to have pain results (p = 0.001). A trend existed toward the presence of a poor quality of reduction (p = 0.05) in patients with a collapse of fracture. Patients with poor preoperative mobility were more likely to have a lower Harris hip score (p = 0.000). CONCLUSION The percutaneous compression plate is an alternative device for the treatment of AO/OTA 31-A3 intertrochanteric femoral fractures. Good fracture reduction and an ideal placement position of the neck screw are important in the success of the device.
منابع مشابه
A comparison of proximal femoral locking plate versus 95-degree angled blade plate in the treatment of reverse intertrochanteric fractures.
OBJECTIVES This study aims to compare the results of the proximal femoral locking plate (PFLP) and the 95°-angled blade plate in the treatment of AO/OTA 31-A3 reverse intertrochanteric fractures with fracture line extending to the greater trochanter. PATIENTS AND METHODS Forty-four patients with reverse intertrochanteric fracture which fracture line extending to the greater trochanter were re...
متن کاملA prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip.
Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, con...
متن کاملHigh Complication Rate in Young Patients With High-Energy Intertrochanteric Femoral Fractures.
Although intertrochanteric femoral fractures in elderly patients are common injuries that have been studied extensively, little has been reported about high-energy intertrochanteric fractures in younger patients. This study examined the injury characteristics and outcomes of high-energy intertrochanteric fractures in patients younger than 65 years treated with either sliding hip screws (SHSs) o...
متن کاملImproved outcome after hip fracture surgery in Norway
Background and purpose - The operative treatment of hip fractures in Norway has changed considerably during the last decade. We used data in the Norwegian Hip Fracture Register to investigate possible effects of these changes on reoperations and 1-year mortality. Patients and methods - 72,741 femoral neck (FFN) fractures and trochanteric fractures in patients 60 years or older were analyzed. Th...
متن کاملDynamic hip screw blade fixation for intertrochanteric hip fractures.
PURPOSE To assess the one-year outcome of a dynamic hip screw (DHS) blade in the treatment of AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures. METHODS 35 men and 65 women aged 47 to 100 (mean, 83) years underwent fixation with a DHS blade for A1 (n=47) and A2 (n=53) intertrochanteric hip fractures after a low-energy injury. Patients were operated on within 48 hours of admission. Antero...
متن کامل