Outcomes of descemet stripping automated endothelial keratoplasty using imported donor corneas
نویسندگان
چکیده
BACKGROUND The lack of development of local donor tissue acquisition in several regions of the world has resulted in the necessity of performing keratoplasty with imported donor corneas. The greatest concern about the use of donor corneas supplied by foreign eye banks is the effect of the increased donor death-to-operation time which inevitably occurs during the tissue recovery, tissue processing, and tissue transfer between the countries. The purpose of this study was to report the outcomes of descemet stripping automated endothelial keratoplasty (DSAEK) using imported donor corneas. METHODS This retrospective, non-comparative case series investigated the outcomes of the 102 consecutive DSAEK procedures using imported donor corneas performed at a single university-based hospital between August 2006-2014. The main outcome measures were postoperative best-corrected visual acuity (BCVA), endothelial cell density (ECD), and complications. RESULTS The mean death-to-operation time was 9.52 ± 1.48 days (range, 8-13). The mean preoperative ECD was 2761 ± 285 cells/mm2. Fuchs' endothelial dystrophy was the predominant indication for grafting. The mean follow-up duration was 65.3 months. Ninety-three eyes had improved vision postoperatively (91.18%). BCVA unchanged in 3 eyes due to preexisting macular scar and advanced glaucoma. Primary graft failure occurred in 6 eyes (5.88%). Of the 93 eyes with improved BCVA, 100% had their best corrected vision within the first 1 year. The mean ECD at 6, 12, 24, 36, and 60 months after surgery was 1762 ± 294 cells/mm2, 1681 ± 284 cells/mm2, 1579 ± 209 cells/mm2, 1389 ± 273 cells/mm2, and 1251 ± 264 cells/mm2 respectively. The mean ECD loss at 6 months, 1 year, 2 years, 3 years, and 5 years after surgery was 36.2%, 39.1%, 42.8%, 49.7%, and 54.7% respectively. The most common complication was graft detachment/dislocation (10.78%). There were no cases of any postoperative infection. CONCLUSIONS DSAEK with imported donor corneas provides rapid and good visual rehabilitation. The percentages of endothelial cell loss were comparable to those achieved in Western series using domestic corneas in which fresher tissues were available for transplantation.
منابع مشابه
Descemet stripping automated endothelial keratoplasty
Endothelial keratoplasty is at present the gold standard for surgical treatment of corneal endothelial pathologies not associated with significant corneal scar. Tremendous progress has been made in recent years in improving the technology of endothelial keratoplasty techniques, such as descemet stripping automated endothelial keratoplasty (DSAEK) and descemet membrane endothelial keratoplasty. ...
متن کاملEventual Endothelial Failure After Initial Corneal Clearing After a Detached Endothelial Graft in Fuchs Dystrophy
mated Bowman layer preparation with a 90to 100-mm-thick donor lamella of anterior stroma (instead of an 8to 12-mm-thick isolated Bowman layer graft). In our experience, the presence of donor stroma seems to degrade the optical quality of the transplanted cornea (as Descemet stripping endothelial keratoplasty/Descemet stripping automated endothelial keratoplasty grafts containing donor stroma ma...
متن کاملUse of Photorefractive Keratectomy Treated Donor Corneas for Endothelial Keratoplasty
357 Corneal transplantation has been widely performed since the first successful surgery was described by Zirm. Recent data from the Eye Bank Association of America (EBAA), the accredited organization that tracks donor quality and volume of surgeries performed anually in the United States, has shown that 46,253 corneal tissues were used for transplantation in 2014 domestically while 76,431 tiss...
متن کاملBanking of donor tissues for descemet stripping automated endothelial keratoplasty.
PURPOSE The demands for precut lamellar grafts for Descemet stripping automated endothelial keratoplasty rose in our eye bank from 74 in 2007 to 408 in 2010. To meet this expanding requirement, we explored the possibility to preserve these preparations in organ culture. METHODS Organ cultured corneas, stored in a medium containing 6% dextran, were mounted on a Moria artificial anterior chambe...
متن کاملDescemet stripping automated endothelial keratoplasty using cultured corneal endothelial cells in a rabbit model.
OBJECTIVE To investigate the feasibility of Descemet stripping automated endothelial keratoplasty (DSAEK) using cultured human corneal endothelial cells (HCECs) in an animal model. METHODS Descemet stripping automated endothelial keratoplasty grafts were produced by seeding cultured HCEC suspensions onto human corneal stromal discs. Three insertion techniques were assessed in an ex vivo model...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -