The Fluctuation of Intraocular Pressure Measured by a Contact Lens Sensor in Normal-Tension Glaucoma Patients and Nonglaucoma Subjects.
نویسندگان
چکیده
PURPOSE We compared the fluctuation of intraocular pressure (IOP) in normal-tension glaucoma (NTG) patients and individuals with nonglaucoma eyes. We obtained continuous IOP values using a SENSIMED Triggerfish contact lens sensor. MATERIALS AND METHODS The eyes of 12 nonglaucoma subjects and 14 NTG patients were examined. In all 26 subjects, the IOP fluctuation was measured continuously for 24 hours with a contact lens sensor. We evaluated the range of IOP fluctuations over the 24-hour period separately for diurnal IOP and nocturnal IOP and identified each subject's maximum value. The range of IOP fluctuation were analyzed, cutoff level of IOP fluctuation was calculated using receiver operating characteristic curve analyses. RESULTS The mean IOP in the NTG eyes was 11.5±2.4 mm Hg and that in the nonglaucoma eyes was 12.7±2.0 mm Hg, a nonsignificantly difference (P=0.175). The 24-hour range of IOP fluctuations in the NTG group was significantly larger than that of the nonglaucoma group (P=0.007). The percentage of NTG patients who had the peak time of IOP fluctuation during nocturnal sleep was 57.1%, whereas the corresponding rate for the nonglaucoma eyes was 91.7%. The cutoff level of IOP fluctuation for glaucoma was 442 mVeq (sensitivity=1.00; specificity=0.571). CONCLUSIONS The range of IOP fluctuation was larger in the eyes with NTG than in the nonglaucoma eyes. This larger fluctuation might be one of the reasons underlying the aggravation of the visual field by NTG. Measurements of 24-hour continuous IOP might be one of the useful methods to distinguish NTG from nonglaucoma eyes.
منابع مشابه
Continuous 24-hour ocular dimensional profile recording in medically treated normal-tension glaucoma
PURPOSE To analyze the 24-hour ocular dimensional profile in normal-tension glaucoma (NTG) patients on medical treatment. METHODS Consecutive, medically treated NTG subjects were recruited from a university eye center. Subjects were on a mean of 1.7±0.7 types of antiglaucoma medications and 56.6% were on a prostaglandin analog. A contact lens-based sensor device was worn in one eye of NTG pat...
متن کاملCorrelation between short-term and long-term intraocular pressure fluctuation in glaucoma patients
PURPOSE We investigated correlations between short-term and long-term intraocular pressure (IOP) fluctuations. METHODS We examined 50 eyes of glaucoma patients who were followed for >2 years. We measured short-term IOP fluctuation using a Triggerfish(®) contact lens sensor (CLS). The short-term IOP fluctuation (mVeq) was defined as the difference between the maximum value and the minimum valu...
متن کاملThe Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry,...
متن کاملTolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
PURPOSE To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sen...
متن کاملThe Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives
Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout the day in patients with glaucoma. The detection and measurement of this fluctuation may help guide the clinical management of glaucomatous individuals. The Sensimed Triggerfish contact lens sensor (CLS), which has recently gained approval for marketing in the USA, is designed to detect int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of glaucoma
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2017