Tolerating vertex distance changes for spherocylindrical corrections.
نویسنده
چکیده
Prescriptions depend on the vertex distance. Although weak prescriptions are insensitive to a vertex distance change, stronger ones must be adjusted if the vertex distance is modified by an appreciable amount. The tolerable amount can be specified for pure spherical powers. For spherocylindrical corrections, the concept of dioptric distance is invoked in this article and applied to the propagation of an astigmatic wavefront. This leads to a simple rule that is well suited to decide on the necessity of modifying a prescription.
منابع مشابه
CASE REPORT Benefit of Adaptive Optics Aberration Correction at Preferred Retinal Locus
Purpose. To investigate the effect of eccentric refractive correction and full aberration correction on both highand low-contrast grating resolution at the preferred retinal locus (PRL) of a single low-vision subject with a long-standing central scotoma. Methods. The subject was a 68-year-old women with bilateral absolute central scotoma due to Stargardt disease. She developed a single PRL loca...
متن کاملM ay 1 99 8 What are the experimentally observable effects of vertex corrections in superconductors ?
What are the experimentally observable effects of vertex corrections in superconductors? Abstract We calculate the effects of vertex corrections, of non-constant density of states and of a (self-consistently determined) phonon self-energy for the Holstein model on a 3D cubic lattice. We replace vertex corrections with a Coulomb pseudopotential, µ * C , adjusted to give the same T c , and repeat...
متن کاملOblique central refraction in tilted spherocylindrical lenses.
Spectacle corrections worn in a frame with a faceform tilt should be used with effective spherocylindrical parameters. For the case of oblique central refraction, Keating presented a procedure to determine these parameters in a third-order approximation. The central equation of his approach, the effective dioptric power matrix, is partly the result of an educated guess. Based on the equations o...
متن کاملPossible experimentally observable effects of vertex corrections in superconductors
We calculate the effects of vertex corrections, of nonconstant density of states and of a ~self-consistently determined! phonon self-energy for the Holstein model on a three-dimensional cubic lattice. We replace vertex corrections with a Coulomb pseudopotential mC* adjusted to give the same Tc , and repeat the calculations, to see which effects are a distinct feature of vertex corrections. This...
متن کاملBenefit of adaptive optics aberration correction at preferred retinal locus.
PURPOSE To investigate the effect of eccentric refractive correction and full aberration correction on both high- and low-contrast grating resolution at the preferred retinal locus (PRL) of a single low-vision subject with a long-standing central scotoma. METHODS The subject was a 68-year-old women with bilateral absolute central scotoma due to Stargardt disease. She developed a single PRL lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 81 11 شماره
صفحات -
تاریخ انتشار 2004