Quantitative blood flow measurement of skeletal muscle using oxygen-15-water and PET.

نویسندگان

  • U Ruotsalainen
  • M Raitakari
  • P Nuutila
  • V Oikonen
  • H Sipilä
  • M Teräs
  • M J Knuuti
  • P M Bloomfield
  • H Iida
چکیده

UNLABELLED The aim of the present study was to evaluate quantitation of muscle blood flow using [15O]H2O and PET. METHODS The autoradiographic (ARG) and the steady-state methods using PET were used to measure femoral muscle blood flow. A simulation study was performed to examine the errors due to contamination of radioactivity in the blood content in muscle tissue, statistical noise and delay and the dispersion of the input curve in the ARG method. Five separate paired muscle blood flow examinations were carried out for comparison of the ARG and the steady-state techniques, including measurement of muscle blood volume in each subject. To obtain the normal range for resting muscle blood flow, additional measurements with the ARG method were performed in 16 normal subjects. RESULTS When the integration time in ARG was increased to 200-300 sec, the errors due to arterial blood volume, statistical noise, delay and dispersion of the input curve were significantly reduced. Muscle blood flow values in the ARG (200 sec) and the steady-state studies were in good agreement, and each provided an estimated accuracy of 5%. Resting muscle blood flow averaged 3.12 +/- 1.55 ml/min.100 g muscle (range 1.43-6.72 ml/min.100 g muscle, n = 18). CONCLUSION The ARG and the steady-state methods provided consistent blood flow values for skeletal muscle when a long tissue integration time (> or = 200 sec) was applied in the ARG study. Based on the lower effective radiation dose and the shorter total scan duration, the ARG method is favored over the steady-state method in the measurement of muscle blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Skeletal muscle blood flow and oxygen uptake at rest and during exercise in humans: a pet study with nitric oxide and cyclooxygenase inhibition.

The aim of the present study was to determine the effect of nitric oxide and prostanoids on microcirculation and oxygen uptake, specifically in the active skeletal muscle by use of positron emission tomography (PET). Healthy males performed three 5-min bouts of light knee-extensor exercise. Skeletal muscle blood flow and oxygen uptake were measured at rest and during the exercise using PET with...

متن کامل

Oxygen-15-water PET assessment of muscular blood flow in peripheral vascular disease.

UNLABELLED To assess quantitatively regional nutritive muscular blood flow in patients with peripheral vascular disease (PVD), we evaluated the utility of PET with 15O-water. METHODS Eight healthy volunteers and 16 patients with angiographically proven PVD were studied. Regional blood flow of the calf was measured with 15O-water PET during rest, after intra-arterial infusion of prostaglandin ...

متن کامل

Role of resistance training with the approach of blood flow restriction in skeletal muscle cell growth

Background: The aim of this study was to investigate the response of ERK1/2 protein and muscular morphological adaptations to a period of resistance training with local blood flow restriction. Materials and methods: Twenty healthy male Wistar rats without clinically evident disease (5 weeks old, 120±7 g weight) were divided into four equal groups: control, control with limited blood flow...

متن کامل

Quantitative Analysis of Coronary Endothelial Function with Generator-produced Rubidium- 82 Pet -comparison with Oxygen 15-labeled Water Pet

Purpose Endothelial dysfunction is the earliest abnormality in the development of coronary atherosclerosis. Rubidium-82 (82 Rb) is a generator-produced positron emission tomography (PET) myocardial perfusion tracer that is becoming more widely used. We aimed to develop a method for quantitative assessment of coronary endothelial function using the myocardial blood flow (MBF) response during a c...

متن کامل

Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography.

BACKGROUND It is recognized that the interplay between myocardial ischemia, perfusion, and oxygenation in the setting of coronary artery disease (CAD) is complex and that myocardial oxygenation and perfusion may become dissociated. Blood oxygen level-dependent (BOLD) cardiovascular magnetic resonance (CMR) has the potential to noninvasively measure myocardial oxygenation, whereas positron emiss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 1997