Visible retinal lesions from ultrashort laser pulses in the primate eye.

نویسندگان

  • C P Cain
  • C A Toth
  • C D DiCarlo
  • C D Stein
  • G D Noojin
  • D J Stolarski
  • W P Roach
چکیده

PURPOSE To evaluate the effects of ultrashort laser pulses of visible wavelengths on the retinas of rhesus monkey eyes and to perform threshold measurements for minimum visible lesions (MVLs) at pulsewidths from nanoseconds to femtoseconds. METHODS Single laser pulses at visible wavelengths were placed within the macular area of live rhesus monkey eyes at varying pulse energies at five pulsewidths (4 ns, 60 ps, 3 ps, 600 fs, and 90 fs). The number of visible lesions was determined after 1 hour and 24 hours postexposure, and a probit analysis was performed for the dosage, causing 50% probability for damage (ED50) as well as the 95% fiducial intervals for ED50. Fluorescein angiography (FA) was performed, and hemorrhagic lesions were recorded as they became visible. RESULTS The ED50 threshold doses at the 1-hour reading, calculated from the measured data, decreased from 1.5 microJ at 4 ns to 0.60 microJ at 600 fs, but it increased to 1.18 microJ at 90 fs. At the 24-hour reading, the ED50 calculated doses decreased from 0.90 microJ at 4 ns down to 0.26 microJ at 600 fs, but it increased to 0.43 microJ at 90 fs. Fluorescein angiography visible lesion ED50 values were all higher than MVL values, showing that FA was not as sensitive in determining damage levels. CONCLUSIONS Laser pulses for pulsewidths between 4 ns and 90 fs are capable of producing visible lesions in monkey eyes with energies less than 1 microJ. Fluorescein angiography is not as sensitive in determining threshold levels as visually observing the retina through a fundus camera.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal effects of ultrashort laser pulses in the rabbit eye.

PURPOSE To evaluate the effects of ultrashort laser pulses from femtoseconds to nanoseconds on the retinas of live rabbit eyes and to determine the energy requirements for visible lesion development. METHODS The retinal effects of laser exposures were examined for laser exposures with pulsewidths ranging from 4 ns to 90 fs, with visible wavelengths of 532 nm for durations > 5 ps and 580 nm fo...

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induced breakdown (LIB) at the site of laser delivery. Single 3-ps pulses of 580-nm ...

متن کامل

Ultrashort laser pulse effects in ocular and related media.

Relatively little experimental and theoretical data exist on the retinal hazards of ultrashort laser pulses operating in the visible and near infrared spectral regions. Because of potential nonlinear effects that can occur from high-peak irradiance, ultrashort laser pulses propagate from the cornea to the retina, we have developed four projects within our Ultrashort Pulse Effects program. First...

متن کامل

Amplification of ultrashort pulses in krypton fluoride at 248 nm.

Ultrashort pulses were produced at 248 nm by using a transverse-discharge KrF* excimer laser as a high-energy amplifier system. Input pulses for the amplifier system were obtained by upconverting the output of a modelocked visible dye laser to the ultraviolet by using nonlinear crystals. Pulses of up to 20 mJ; in energy with 10-30-psec duration were obtained at 10 pulses/sec. The output pulse w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 1995