Densitometry Guidance

نویسندگان

  • E. Michael Lewiecki
  • Neil Binkley
  • Sarah L. Morgan
  • Christopher R. Shuhart
  • Bruno Muzzi Camargos
  • John J. Carey
  • Catherine M. Gordon
  • Lawrence G. Jankowski
  • William D. Leslie
چکیده

Dual-energy X-ray absorptiometry (DXA) is a technology that is widely used to diagnose osteoporosis, assess fraclure risk, and monitor changes in bone mineral density (BMD). The clinical utility of DXA is highly dependent on the quality of the scan acquisition, analysis, and interpretation. Clinicians are best equipped to manage patients when BtviD measurements are correct and interpretation follows well-established standards. Poor-quality acquisition, analysis, or interpretation of DX/\ data may mislead referring clinicians, re• suiting in unnecessary diagnostic evaluations, failure to evaluate when needed, inappropriate treatment, or failure to provide medical treatment, with potentially ineffective, harmful, or costly consequences. Misallocation of limited healthcare resources and poor treatment decisions can be minimized, and patient care optimi1.ed, through meticulous attention to DXA instrument calihration, data acqui,;ition and analysiR,interpretation, and reporting. This document from the International Society for Clinical Densitometry describes quality standards for BMD testing at DXA facilities worldwide to provide guidance for DXA supervisors, technologists, interpreters, and clinicians. High-quality DXA testing is necessary for correct diagnostic classification and optimal fracture risk assessment, and is essential for BMD monitoring. Received 03/7/16; Accepted 03/8/16. Disclosure: EML has served on scientific advisory boards for Amgen, Merck, 'Eli Lilly, Radius Health, AgNovos Healthcare, Alexion, Shire, and AbbVie-. NB has served on scientific advisory boards for Amgen, Merck, and Eli Lllly. CRS serves on scientific and commercial advisory boards for Amgen. WDL has received speaker fees from Amgen, Eli Lily, and Novartis. BMC has ·received speaker fees from GE, Hologic, Ache, E.MS. Hypermarcas and Medimaps. EML has received institutional grant/research support from Amgen. Merck, and F.li Tilly. NB has received institutional grant/research support from Amgen, Merck, F.li T .illy, and GR Healthcare.WDT. received research granls from Amgen (all paid to the institution). JJC was served oo scientific advisory boards for MSD, Abbvie,Amgen, Prcoter & Gamhle, Hospira,Servier, Pfizer, Bristol Myers Squihh, and Roche, and received speaker fee.s from MSD, Roche, Ahhvie, Eli-Lilly, Bristol Myers Squibb. Hospira, and Pfizer. Research Grants: Abbvie, MSD. P&G, and Centocor. ~ Address correspondence to: E. Michael r .ewiecki, MD, New Mexico Clinical Research & Osteoporo~s Center, 300 Oak St. NF., Alhuquerque, NM 87106. F.-mail: mlcwiccki@.>gmail.com

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical report—bone densitometry in children and adolescents.

Concern for bone fragility in children and adolescents has led to increased interest in bone densitometry. Pediatric patients with genetic and acquired chronic diseases, immobility, and inadequate nutrition may fail to achieve the expected gains in bone size, mass, and strength, which leaves them vulnerable to fracture. In older adults, bone densitometry has been shown to predict fracture risk ...

متن کامل

Bone Densitometry in Children and Adolescents.

Concerns about bone health and potential fragility in children and adolescents have led to a high interest in bone densitometry. Pediatric patients with genetic and acquired chronic diseases, immobility, and inadequate nutrition may fail to achieve expected gains in bone size, mass, and strength, leaving them vulnerable to fracture. In older adults, bone densitometry has been shown to predict f...

متن کامل

The Official Positions of the International Society for Clinical Densitometry: body composition analysis reporting.

Dual-energy x-ray absorptiometry (DXA) measurements of body composition increasingly are used in the evaluation of clinical disorders, but there has been little guidance on how to effectively report these measures. Uniformity in reporting of body composition measures will aid in the diagnosis of clinical disorders such as obesity, sarcopenia, and lipodystrophy. At the 2013 International Society...

متن کامل

Dual-energy X-ray aborptiometry assessment in children and adolescents with diseases that may affect the skeleton: the 2007 ISCD Pediatric Official Positions.

The Task Force focusing on the use of dual energy X-ray absorptiometry (DXA) in children and adolescents with diseases that may affect the skeleton reviewed over 300 articles to establish the basis for the Official Positions. A significant number of studies used DXA-based outcome measures to assess the effects of specific interventions and charted the natural history of incremental changes in b...

متن کامل

Official Positions for FRAX® clinical regarding international differences from Joint Official Positions Development Conference of the International Society for Clinical Densitometry and International Osteoporosis Foundation on FRAX®.

Osteoporosis is a serious worldwide epidemic. Increased risk of fractures is the hallmark of the disease and is associated with increased morbidity, mortality and economic burden. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors, femoral neck BMD, country specific mortality and fracture data and calculates the 10 year frac...

متن کامل

Corneal Densitometry as a Tool to Measure Epithelial Ingrowth After Laser In Situ Keratomileusis.

PURPOSE This study evaluates the correlation between corneal densitometry and epithelial ingrowth (EI) after laser in situ keratomileusis (LASIK). METHODS Corneal densitometry of 3 patients who developed EI after LASIK was measured with the Oculus Pentacam. Corneal densitometry readings of each patient were obtained preoperatively and postoperatively after ingrowth was discovered. Densitometr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017