99mTechnetium Sestamibi-123Iodine Scintigraphy Is More Accurate Than 99mTechnetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism

نویسندگان

  • Eeva M. Ryhänen
  • Jukka Schildt
  • Ilkka Heiskanen
  • Mika Väisänen
  • Aapo Ahonen
  • Eliisa Löyttyniemi
  • Camilla Schalin-Jäntti
  • Matti J. Välimäki
چکیده

Objectives. Studies comparing outcome of single-(99m)Tc-methoxyisobutylisonitrile ((99m)Tc-sestamibi) and dual-tracer (99m)Tc-sestamibi scintigraphy in combination with (123)I before primary surgery of primary hyperparathyroidism (PHPT) are scarce. Methods. We compared (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi in a single-centre retrospective series of 269 PHPT patients. The results were related to laboratory, surgical and histological findings. Results. (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were positive in 206 (76.6%) and 111 (41.3%) of 269 patients, respectively (P < 0.001). Accuracies for (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were 63.4% and 34.9%, respectively (96% CI, P < 0.001). Prevalence of multiglandular disease was 15.2%. In multiglandular disease, (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi revealed 43.8 and 22.1% of pathological glands, respectively (P < 0.001). Cure rate was similar for patients with (191/206; 92.7%) and without (59 of 63; 93.7%) a positive (99m)Tc-sestamibi/(123)I finding. Duration of targeted surgery (one or two quadrants) was 21 and 15 minutes shorter than bilateral neck exploration, respectively (both P < 0.001). Higher serum calcium (P = 0.014) and PTH (P = 0.055) concentrations and larger tumours (P < 0.001) characterized the 206 patients with a positive preoperative scan who were cured by removal of a single adenoma. Conclusions. (99m)Tc-sestamibi/(123)I scintigraphy is more accurate than (99m)Tc-sestamibi before surgery of PHPT. However, outcome of surgery is not determined by scintigraphy alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parathyroid adenoma Localization

 Background: Bilateral neck exploration is the gold standard for parathyroid adenoma localization in primary hyperparathyroidism. But surgeons do not have adequate experience for accurate surgical exploration and new methods are developed for surgery like unilateral exploration and minimally invasive surgery, thus, preoperative localization could reduces time and stress in surgical performance....

متن کامل

Planar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism?

UNLABELLED All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent...

متن کامل

Dual Localization with Ultrasound and Iodine 123 and Technetium (99mTc) Sestamibi Scintigraphy is Superior to Single Imaging Modalities in Facilitating Minimally Invasive Parathyroidectomy for Primary Hyperparathyroidism

Primary hyperparathyroidism is caused by a single parathyroid adenoma in the majority of patients. Localization of parathyroid adenomas prior to surgery has the benefit of allowing a minimally invasive approach. Over the years, multiple imaging modalities have been employed in an attempt to identify the site preoperatively, with varying degrees of success. In this study, we explore the accuracy...

متن کامل

Parathyroid adenoma Localization

BACKGROUND Bilateral neck exploration is the gold standard for parathyroid adenoma localization in primary hyperparathyroidism. But surgeons do not have adequate experience for accurate surgical exploration and new methods are developed for surgery like unilateral exploration and minimally invasive surgery, thus, preoperative localization could reduces time and stress in surgical performance. ...

متن کامل

Comparison of radiation exposure and cost between dynamic computed tomography and sestamibi scintigraphy for preoperative localization of parathyroid lesions.

IMPORTANCE Dynamic computed tomography (CT) is emerging as a first-line alternative to sestamibi scintigraphy for preoperative localization of parathyroid lesions. In recent years, there has been increased concern over the impact of radiation exposure from medical imaging, as well as on the cost of diagnostic medical procedures. An ideal diagnostic procedure would be cost effective while minimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015