Circuit design for reproducible on-site measurements of transfer function on large power transformers using the SFRA method
نویسندگان
چکیده
By the analysis of transfer function mechanical deformations or displacements of transformer windings can be detected. For on site measurements on large power transformers essential attention has to be put on accurate cabling and handling of grounding conductors. Of further concern is the selection of a meaningful upper frequency limit, from where beyond measurements of frequency responses are not practicable on site. A set-up concept for reproducible measurements that has been developed by the authors shows satisfying results. Investigations on the transfer function of power transformers identical in construction have been carried out: Depending on the type, size and winding construction the transfer function of a winding system of identical transformers is well comparable to frequencies above 1 MHz. A mathematical approach to evaluate the quality of different comparison methods using the coherence function is presented.
منابع مشابه
Field Experience with Sweep Frequency Response Analysis for Power Transformer Diagnosis
Abstract—Sweep frequency response analysis has been turning out a powerful tool for investigation of mechanical as well as electrical integration of transformers. In this paper various aspect of practical application of SFRA has been studied. Open circuit and short circuit measurement were done on different phases of high voltage and low voltage winding. A case study was presented for the trans...
متن کاملInfluence of Converter and inverter on dynamic behavior of the GMAW process
This paper investigates the dynamic behavior of Gas Metal Arc Welding (GMAW) process for two types of power supplies –inverter and rectifier- for short circuit transfer mode. The large ripples on the rectifier power source are able to perturb the metal transfer mode. In this experimental work some operating points in the short circuit mode have been selected using an automatic pipeline welding ...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملDetection of Mechanical Deformation in Old Aged Power Transformer Using Cross Correlation Co-Efficient Analysis Method
s – Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electro...
متن کاملDesign of power-efficient adiabatic charging circuit in 0.18μm CMOS technology
In energy supply applications for low-power sensors, there are cases where energy should be transmitted from a low-power battery to an output stage load capacitor. This paper presents an adiabatic charging circuit with a parallel switches approach that connects to a low-power battery and charges the load capacitor using a buck converter which operates in continuous conduction mode (CCM). A gate...
متن کامل