The Evaluation of Cardiac Troponin I Assays Measured Radiometer AQT90 Flex and ReLIA Analyzers and Determination of Heterophilic Antibody Positivity Rate
نویسندگان
چکیده
Measurement of cardiac troponin I (cTnI) is important for the diagnosis of myocardial infarction and for risk stratification. The aim of this study was to compare the diagnostic performance of AQT90 Flex cTnI and ReLIA cTnI assays as based Vidas Ultra cTnI results, and also determine rate of the heterophilic antibody (HAs) positivity. A total of 246 cTnI and HAs assays were performed from the blood and serum samples. The diagnostic cut-off value for cTnI assays was accepted as 0.01 μg/L, 0.023 ng/mL and 0.15 ng/mL for Vidas Ultra, AQT90Flex and ReLIA analyzers, respectively. Sensitivity, specificity, predictive value of positive and negative test, false positive and negative rate and efficiency were calculated. The sensitivity, negative predictive value, false positivity rate and accuracy of cTnI assay performed on AQT90 Flex analyzer were higher than cTnI assay performed on ReLIA analyzer. However, cTnI assay performed on ReLIA analyzer have higher specificity and false negativity rate as compared to cTnI test performed on AQT90 Flex analyzer. The agreement of cTnI results were calculated using of kappa analysis. The analysis revealed a substantial agreement between cTnI assays performed on Vidas Ultra and AQT90 Flex analyzer (p<0.001, κ=0.618), and fair agreement between cTnI assays performed on Vidas Ultra and ReLIA analyzer (p<0.001, κ=0.373).The positivity rate of HAs was found as 4.87%. The results of the study showed that AQT90Flex cTnI assay has higher sensitivity and accuracy, lower specificity and false negativity rate as compared to ReLIA cTnI assay. However, fairly lower heterophilic antibody positivity rate is found
منابع مشابه
Comments on Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study
Dear Editor We read with interest the article “Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study” by Perveen et al. published in Ann Lab Med 2013;33:34-38 [1]. In this article, the authors compared the performance of the D-dimer assays on the AQT90 FLEX analyzer (Radiometer Medical Aps, Åkandevej, Denmark) and the VIDAS analyzer (bioMérieux SA, RCS Lyon, France)....
متن کاملEvaluation of cardiac troponin I (cTnI), electrocardiography, creatine kinase (CK) and aspartate aminotransferase (AST) in diagnosis of selenium deficiency in Markhoz goat kids breed
BACKGROUND: Cardiac Troponin I (cTnI) is known as a cardiac biomarker in determining the myocardial damage of diseases which affect the heart muscle. OBJECTIVES: This study aims to evaluate the serum cTnI concentration in Markhoz Breed goats suffering selenium (Se) deficiency and its correlation with electrocardiographic parameters, and activity of creatine kinase (CK) and aspartate aminotransf...
متن کاملبررسی تروپونین I در بیماران هیپوتیروئید مراجعه کننده به درمانگاه غدد بیمارستان حضرت رسول اکرم(ص)، انیستیتو غدد داخلی و متابولیسم
Background: With increase in the age there is an increase in both the incidence of hypothyroidism and cardiovascular diseases. We wanted to see whether hypothyroidism caused false positivity in patients who did not have cardiovascular problems or not. In hypothyroid state, creatine kinase leaks into blood. Troponin I in small amount persists in Cytosolic pool (the same site of creatine kina...
متن کاملAnalysis of the relation between coping ways with stress and Cardiac Biomarker Troponin I in coronary heart disease patients
Introduction: Coping ways with stress in coronary heart disease patients can lead to significant changes in levels of Cardiac Biomarker Troponin I, but researchers had not explored it empirically. So, the main objective of this study was to identify the relationship between coping ways with stress and Cardiac Biomarker Troponin I and also, finding coping ways that predict changes in the concent...
متن کاملCorrelation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome
Background and Objectives: The aim of this study was to survey the relationship between the level of creatinine,cardiac troponins serum and the function of the left ventricle in patients with kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample was150 patients with nondialysis chronic kidney disease without acute coronary syndrome, hospitalized at I...
متن کامل