Comparison of assay systems for detecting antibodies to nuclear ribonucleoproteins.
نویسندگان
چکیده
The specificity and sensitivity of two commercial enzyme linked immunosorbent assays (ELISAs), Diamedix (Miami, Florida) and Lipogen (Noxville, Tennessee), were assessed and compared with haemagglutination and immunodiffusion assays. Sera from 53 patients with various connective tissue disorders were examined for the presence of antibodies to nuclear antigens (ANA), double stranded DNA (dsDNA), Sm, RNP, SSA/Ro, and SSB/La. Of the 53 patients, 42 were ANA positive, 11 were ANA negative, and 22 had antibodies to dsDNA. Seven patients had antibodies to Sm by haemagglutination assay; these were also positive in both ELISA systems (only five of the seven patients were assayed by the Lipogen ELISA system). Two additional Sm positive values were obtained in each of the ELISA systems but only one of these was positive in both. Ten positive RNP results were obtained by haemagglutination and nine of these were also positive by the Diamedix ELISA. Only eight samples were tested by the Lipogen assay and seven of these were positive. Three additional RNP positive values were obtained by the Diamedix and six by the Lipogen ELISA assays. Of these, only two were positive in both. Antibodies to SSA/Ro were obtained in 11 patients by immunodiffusion and lines of partial identity were observed in nine. SSB/La antibodies were positive in six patients and two had lines of partial identity. All the SSA/Ro and SSB/La positive sera were also positive in both ELISA systems. Moreover, eight additional SSA/Ro positive values were obtained in each of the ELISAs, four of which had partial identity lines in the immunodiffusion assay. Furthermore, three additional SSB/La positive values were obtained by the Diamedix and four by the Lipogen assays. Of these, only two were positive in both ELISAs. This study shows that the above ELISAs are comparable in specificity and sensitivity with haemagglutination assay for detection of antibodies to Sm and RNP antigens and are more sensitive than immunodiffusion for the detection of SSA/Ro and SSB/La antigens.
منابع مشابه
Comparison of Micro Neutralization Test with Hemadsorption-Inhibition Test, and Immunoflrorescence Technique for Detecting Mumps Antibodies
متن کامل
A multiple-antigen detection assay for tuberculosis diagnosis based on broadly reactive polyclonal antibodies
Objective(s): Detection of circulating Mycobacterium tuberculosis (M. tuberculosis) antigens is promising in Tuberculosis (TB) diagnosis. However, not a single antigen marker has been found to be widely expressed in all TB patients. This study is aimed to prepare broadly reactive polyclonal antibodies targeting multiple antigen markers (multi-target antibodies) and evaluate their efficacies in ...
متن کاملComparison of multiplex, ELISA and immunofluorescence for detecting autoantibodies in JIA patients
Purpose Detection of antinuclear antibodies has traditionally been performed by immunofluorescence (IFA) on fixed culture cells or tissues with reactivity being reported as a fluorescence pattern associated to one or more nuclear antigens. For this study, we compared results from IFA testing with a multiplex antinuclear antibody assay on a panel of patient serum samples previously evaluated by ...
متن کاملDevelopment of a Western Blot Assay for Detection of Antibodies against HSV Using Purified HSV Virions Prepared by Sucrose Density Gradient
Objective(s) Herpes simplex viruses (HSVs) have widespread and ubiquitous prevalence in the human population and they have received a great deal of attention due to the range of diseases, they caused as a result of an infection. It seems that the fast and reliable diagnostic methods are needed for detecting the herpes simplex virus type 1 (HSV1) antibodies especially in patients with HSV encep...
متن کاملAnti-Nuclear Antibodies in Patients with Polycystic Ovary Syndrome before and after Laparoscopic Electrocauterization
Polycystic ovary syndrome (PCOS) has been suggested to be linked with autoimmune processes. Laparoscopic ovarian electrocauterization has the potency to stimulate more autoimmune reactions in PCOS patients. In the present study, we considered anti-nuclear antibodies (ANAs) as the hallmark of autoimmune reactions, and investigated the serum level of these antibodies in 35 patients with PCOS (21-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 44 8 شماره
صفحات -
تاریخ انتشار 1991