Evaluation of neonatal BH4 loading test in neonates screened for hyperphenylalaninemia.

نویسندگان

  • François Feillet
  • Céline Chery
  • Fares Namour
  • Antoine Kimmoun
  • Elisabeth Favre
  • Elisabeth Lorentz
  • Shyue-Fang Battaglia-Hsu
  • Jean-Louis Guéant
چکیده

BACKGROUND The outcome in phenylketonuria is related to the early diagnosis and management due to neonatal screening. AIMS To assess the interest of tetrahydrobiopterin (BH4) loading test and phenylalanine hydroxylase (PAH) genotyping in the management of neonates with hyperphenylalaninemia (HPA). STUDY DESIGN We evaluate the effectiveness of a BH4 loading test (20 mg/kg) in ten neonates screened for HPA. We evaluated the time required to reach a target plasma Phenylalanine (Phe) level below 300 micromol/l. We compared these ten BH4-loaded patients to the 10 previous neonates non-loaded with BH4. In all these patients, the PAH genotype was determined. RESULTS One loaded patient had biopterin synthesis deficiency and has been retrieved from statistical analysis. All others patients have PAH deficiency. Between the BH4 loaded group (L) and the BH4 non-loaded group (NL), a statistically significant difference was observed in the average time required to reached the target Phe level (13.56 +/- 4.30 (L) vs. 20.6 +/- 7.59 days (NL) [p < 0.02]). Results of the genotyping from all but one of these 19 patients indicated that among all mutations present in this patient population, there were 4 known PAH mutations associated with BH4 responsiveness (p.R261Q, the p.V388 M, the p.E390G and the p.Y414C). These mutations were found in 4 non-loaded and 6 loaded patients. Two patients had a more than 90% reduction in their plasma Phe level within 24 h after the load. One of these patients had a PTPS deficiency. The other fully responsive patient (p.Y414C and IVS10-11G>A) has been treated with BH4 from birth with an excellent metabolic control for three years now. CONCLUSION BH4 loading test improves the management of HPA. It allows an immediate identification of the children fully responsive to BH4. Our results therefore suggest the incorporation of BH4 loading test in the management of neonates screened for HPA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma biopterin levels and tetrahydrobiopterin responsiveness.

Tetrahydrobiopterin (BH4) responsive hyperphenylalaninemia (HPA) with a mutant phenylalanine hydroxylase (PAH) gene was found during neonatal screening for PKU. This study determined blood BH4 and phenylalanine in two patients with hyperphenylalaninemia following oral load with BH4 10 mg/kg. Our patients underwent neonatal screening for PKU, had normal biopterin metabolism and their PAH mutatio...

متن کامل

Long-term treatment with tetrahydrobiopterin increases phenylalanine tolerance in children with severe phenotype of phenylketonuria.

Hyperphenylalaninemia caused by phenylalanine hydroxylase (PAH) deficiency requires lifelong rigorous diet starting in early infancy to prevent severe neurodevelopmental handicap. In a considerable number of children with mild hyperphenylalaninemia, long-term tetrahydrobiopterin (BH4) treatment significantly improves phenylalanine (phe) tolerance, but it has never been investigated in classic p...

متن کامل

Tetrahydrobiopterin responsiveness: results of the BH4 loading test in 31 Spanish PKU patients and correlation with their genotype.

Tetrahydrobiopterin (BH4) responsiveness in patients with mutations in the phenylalanine hydroxylase (PAH) gene is a recently recognized subtype of hyperphenylalaninemia characterized by a positive BH4 loading test. According to recent estimates, this phenotype may be quite common, suggesting that a large group of individuals may benefit from BH4 substitution, eliminating the need of life-long ...

متن کامل

Genotype-phenotype associations in French patients with phenylketonuria and importance of genotype for full assessment of tetrahydrobiopterin responsiveness

BACKGROUND Mutations in Phenylalanine Hydroxylase (PAH) gene cause phenylketonuria. Sapropterin (BH4), the enzyme cofactor, is an important therapeutical strategy in phenylketonuria. However, PAH is a highly polymorphic gene and it is difficult to identify BH4-responsive genotypes. We seek here to improve prediction of BH4-responsiveness through comparison of genotypes, BH4-loading test, predic...

متن کامل

The neonatal tetrahydrobiopterin loading test in phenylketonuria: what is the predictive value?

BACKGROUND It is unknown whether the neonatal tetrahydrobiopterin (BH4) loading test is adequate to diagnose long-term BH4 responsiveness in PKU. Therefore we compared the predictive value of the neonatal (test I) versus the 48-h BH4 loading test (test II) and long-term BH4 responsiveness. METHODS Data on test I (>1991, 20 mg/kg) at T = 8 (n = 85) and T = 24 (n = 5) were collected and compare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Early human development

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2008