Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.
نویسندگان
چکیده
OBJECTIVES To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. DESIGN AND METHODS A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. RESULTS The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to <LoD. CONCLUSIONS Utilization of cFab-fragments enabled the development of a sensitive (LoD=3.3ng/L) immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values.
منابع مشابه
Degradation of cardiac troponin I in serum complicates comparisons of cardiac troponin I assays.
BACKGROUND Up to a 20-fold variation in serum cardiac troponin I (cTnI) concentration may be observed for a given patient sample with different analytical methods. Because more limited variation is seen for control materials and for purified cTnI, we explored the possibility that cTnI was present in altered forms in serum. METHODS We used four recombinantly engineered cTnI fragments to study ...
متن کاملDevelopment of a qualitative sequential immunoassay for characterizing the intrinsic properties of circulating cardiac troponin I.
BACKGROUND With myocardial infarction (MI), cardiac troponin is released from the heart into circulation, where it can be detected with immunoassays independently quantifying cardiac troponin I (cTnI) or cTnT. There is, however, no single immunoassay that sequentially probes the posttranslational modification status of cTnI or directly characterizes whether circulating cTnI is bound to cTnC and...
متن کاملChimeric cardiac troponin I antibodies
most assay manufacturers take additional measures during the assay development. The most frequent procedure involves suppressing the non-specific binding with blocking reagents, which vary from normal mouse IgG to more refined formulations. Whilst in most cases these measures are adequate, they do result in additional costs in terms of both material and labor. The effect of HAMA can also be sup...
متن کاملAssay Development of a Serum Marker for Myocardial Injury: Experiences with an Avian anti-Troponin I Antibody.
The diagnosis of acute myocardial infarction is still difficult in certain cases. The measurement of human cardiac Troponin I, a new marker for heart muscle cell necrosis, can help to support current procedures of diagnosis. The detection is usually done with antibodies in a sandwich immunoassay. For development of such a test for human cardiac Troponin I on the automated analyser Technicon Imm...
متن کاملبررسی تروپونین I در بیماران هیپوتیروئید مراجعه کننده به درمانگاه غدد بیمارستان حضرت رسول اکرم(ص)، انیستیتو غدد داخلی و متابولیسم
Background: With increase in the age there is an increase in both the incidence of hypothyroidism and cardiovascular diseases. We wanted to see whether hypothyroidism caused false positivity in patients who did not have cardiovascular problems or not. In hypothyroid state, creatine kinase leaks into blood. Troponin I in small amount persists in Cytosolic pool (the same site of creatine kina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biochemistry
دوره 48 4-5 شماره
صفحات -
تاریخ انتشار 2015