Incidence of retear with double-row versus single-row rotator cuff repair.
نویسندگان
چکیده
Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed.
منابع مشابه
Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears
BACKGROUND It is a challenge for orthopaedic surgeons to treat massive rotator cuff tears. The optimal management of massive rotator cuff tears remains controversial. Therefore, the goal of this study was to compare arthroscopic single- versus double-row rotator cuff repair with a larger sample size. MATERIAL AND METHODS Of the subjects with massive rotator cuff tears, 146 were treated using ...
متن کاملDouble-row rotator cuff repair yields improved tendon structural integrity, but no difference in clinical outcomes compared with single-row and triple-row repair: a systematic review
Rush LN, et al. JISAKOS 2017;2:260–268. doi:10.1136/jisakos-2016-000069. Copyright © 2017 ISAKOS AbstrAct Importance Techniques for arthroscopic rotator cuff repair are rapidly evolving. Single-row (SR) and doublerow (DR) repair techniques have been well described, but recent studies have suggested the biomechanical superiority of transosseous-equivalent (TOE) DR repairs and triple-row (TR) rep...
متن کاملMeta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair
CONTEXT Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. OBJECTIVE To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. DATA SOURCES Published literature from January 1980 to April 20...
متن کاملBiomechanical Evaluation of Rotator Cuff Repair Complex: Single vs. Double Row Repair
INTRODUCTION: Current rotator cuff repairs have a high incidence of asymptomatic defects [1]. Researchers have quantified that current repairs only restore a maximum of 67% of the original footprint of the rotator cuff [2]. Recently, double row suture anchors repair techniques have been reported that could re-establish the footprint of the rotator cuff [3,4]. Reports have shown that the biomech...
متن کاملMinimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears
Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double–row suture-bridge configuration (2×2 anchor with 4×4 suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using 2×2 anchor double-row ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 37 11 شماره
صفحات -
تاریخ انتشار 2014