Atrioventricular Pressure Half-Time

نویسنده

  • ALBERT J. LIBANOFF
چکیده

was less than 25 msec. Although exercise increased the atrioventricular pressure gradient, heart rate, and cardiac output significantly, the half-time was affected only slightly. Mitral regurgitation of various severities did not affect the half-time. The half-time appears to vary inversely with the anatomic orifice area of the mitral valve. The determination of the half-time obviates the need for the commonly used exercise test for the evaluation of mitral stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound.

The mean pressure drop across the mitral valve and atrioventricular pressure half-time were measured noninvasively by Doppler ultrasound in 40 normal subjects, in 17 patients with mitral regurgitation, 32 patients with mitral stenosis and 12 with combined stenosis and regurgitation. In normal subjects pressure half-times were 20--60 msec, in patients with isolated mitral regurgitation 35--80 ms...

متن کامل

Pacing for atrioventricular block.

to the editor: The report by Toff and colleagues on the United Kingdom Pacing and Cardiovascular Events (UKPACE) trial (July 14 issue), 1 evaluating cardiovascular end points in elderly patients with atrioventricular block, showed that the use of dual-chamber pacing to maintain atrioventricular synchrony conferred no survival advantage over the use of single-chamber pacing. These results may be...

متن کامل

BRIEF COMMUNICATIONS Long-Term Responses of Atrial Rate and Peripheral Resistance to Changes in Ventricular Pacing Rate in Awake Dogs with Atrioventricular Block

We wished to see if a maintained change in pressure at the baroreceptors leads to a maintained or a transient change in heart rate and total peripheral resistance, and if long-term changes in rate and resistance paralleled one another. In awake dogs with intact baroreceptors and complete atrioventricular block, ventricular rate was held alternately at high (90 beats/min) and low (50 beats/min) ...

متن کامل

Long-term responses of atrial rate and peripheral resistance to changes in ventricular pacing rate in awake dogs with atrioventricular block.

We wished to see if a maintained change in pressure at the baroreceptors leads to a maintained or a transient change in heart rate and total peripheral resistance, and if long-term changes in rate and resistance paralleled one another. In awake dogs with intact baroreceptors and complete atrioventricular block, ventricular rate was held alternately at high (90 beats/min) and low (50 beats/min) ...

متن کامل

Real-time and simultaneous measurement of tricuspid orifice and tricuspid anulus areas in anesthetized dogs.

Tricuspid valve orifice and tricuspid valve anulus areas were measured simultaneously in the anesthetized dog with a newly developed area-measuring system based on electromagnetic induction. This system permitted real-time monitoring of the area enclosed by the edges of valve leaflets and by the juncture of the valve leaflet and the cardiac wall in situ, without artificial constraint to the val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005