Electrochemically deposited iridium oxide reference electrode integrated with an electroenzymatic glutamate sensor on a multi-electrode array microprobe.
نویسندگان
چکیده
An implantable micromachined multi-electrode array (MEA) microprobe modified for utilization as a complete electrochemical biosensor for rapid glutamate detection is described. A post-fabrication method for electrochemical deposition of an iridium oxide (IrOx) film onto a designated microelectrode enabled incorporation of an IrOx reference electrode (RE) on the microprobe. The on-probe IrOx RE provides an alternative to the commonly utilized Ag/AgCl wire RE, which has been shown to be unstable and to cause an inflammatory response in living tissue. The IrOx film electrodeposited onto a platinum site was tested as part of a complete chemical sensing system that included a platinum counter electrode and enzymatic glutamate sensing electrodes all on a single silicon-based MEA platform. The thin film IrOx was mechanically robust enough to endure conditions of repeated heating and wetting during the MEA fabrication process. The pH dependence of the IrOx open circuit potential (OCP) was measured at -77±0.4 mV/pH and remained stable over a two-week period. The on-probe IrOx RE was tested in a two- and three-electrode system with glutamate biosensors. The biosensors were shown to detect a physiologically relevant range of glutamate concentrations and to reject the interferents, dopamine and ascorbic acid. By incorporating all of the electrodes onto a single device, baseline noise was reduced by an average of ∼61% in vitro and ∼71% in vivo with reduced tissue damage, since only a single probe needed to be implanted.
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملSol-Gel Deposition of Iridium Oxide for Biomedical Micro-Devices
Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabrication method yields reliable miniature on-probe IrOx electrodes with long lifetime, high stability and repeatability. Such sensors can be used for...
متن کاملElectrocatalytic Oxidation of Hydrazine at Epinephrine Modified Glassy Carbon Electrode (EPMGCE).
A thin film of epinephrine (EP) was electrochemically deposited on the surface of glassy carbon electrode previously activated in NaHCO3 solution. The cyclic voltammograms of the modified electrode indicate that the surface confined EP are strongly dependent on the solution pH, as expected for quinone/hydroquinone functionalities. The EP-modified glassy carbon electrode exhibited...
متن کاملOn-chip multi-electrochemical sensor array platform for simultaneous screening of nitric oxide and peroxynitrite.
In this work we report on the design, microfabrication and analytical performances of a new electrochemical sensor array (ESA) which allows for the first time the simultaneous amperometric detection of nitric oxide (NO) and peroxynitrite (ONOO(-)), two biologically relevant molecules. The on-chip device includes individually addressable sets of gold ultramicroelectrodes (UMEs) of 50 µm diameter...
متن کاملFabrication of a Microneedle/CNT Hierarchical Micro/Nano Surface Electrochemical Sensor and Its In-Vitro Glucose Sensing Characterization
We report fabrication of a microneedle-based three-electrode integrated electrochemical sensor and in-vitro characterization of this sensor for glucose sensing applications. A piece of silicon was sequentially dry and wet etched to form a 15 × 15 array of tall (approximately 380 µm) sharp silicon microneedles. Iron catalyst was deposited through a SU-8 shadow mask to form the working electrode ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 42 شماره
صفحات -
تاریخ انتشار 2013