Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm.
نویسندگان
چکیده
Whole-body PET scanning for an oncology study produces a large number of transaxial images by data acquisition over multiple bed positions. The sagittal and coronal reformatted images are often used for better understanding of radioisotope distribution. We reduced the number of PET images by calculating projection images and evaluated the merit of additional data processing for the visualization and detection of tumors. After reconstructing whole-body 18F-FDG PET images (6-8 bed positions) of eight cancer patients, antero-posterior and lateral projection images were calculated by the maximum intensity projection (MIP) algorithm, the standard deviation projection (SD) algorithm and the summed voxel projection (SUM) algorithm. The projection images were compared with 2D whole-body images for visualizing foci. The focal uptakes of various positions in original whole-body PET data (294-392 transaxial images) were visualized on only two MIP reformatted images when superimposition of hot spots did not occur. Even if one hot spot was superimposed over the other hot spot, we could recognize the existence of at least one focus and determine the true positions of the hot spots from corresponding transaxial images. The SD image was found inferior for showing a contrast of small foci to the corresponding MIP images in the neck, mediastinum and abdomen. The SUM image failed to visualize many metastatic lesions. MIP is a promising technique for the easy preliminary assessment of tumor distribution in oncologic whole-body PET study.
منابع مشابه
Target detection Bridge Modelling using Point Cloud Segmentation Obtained from Photogrameric UAV
In recent years, great efforts have been made to generate 3D models of urban structures in photogrammetry and remote sensing. 3D reconstruction of the bridge, as one of the most important urban structures in transportation systems, has been neglected because of its geometric and structural complexity. Due to the UAV technology development in spatial data acquisition, in this study, the point cl...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملSplines and wavelets for medical imaging
Both types of representations are useful when one wishes to consider image data as a continuum rather than a discrete array of pixels. Such a continuous modeling of the data is often required in medical imaging. Interpolation, in particular, plays a crucial role at various stages of processing [18, 24]. For instance, it is present—explicitly or not—for tomographic reconstruction, irrespective o...
متن کامل[Quantitative evaluation of block-iterative reconstruction image in PET: comparison of the dynamic RAMLA algorithm and OSEM algorithm].
PURPOSE Iterative reconstruction has been successfully used in whole-body PET imaging because of reductions in noise and scanning time. However, there are plural algorithms for image reconstruction such as OSEM, RAMLA and Dynamic RAMLA. Dynamic RAMLA (DRAMA) is an iterative algorithm similar to RAMLA, but the relaxation parameter is controlled in such a way that the propagation of noise from pr...
متن کاملThe direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction.
The aim of this work is to calculate, directly from projection data, concise images characterizing the spatial and temporal distribution of labelled compounds from dynamic PET data. Conventionally, image reconstruction and the calculation of parametric images are performed sequentially. By combining the two processes, low-noise parametric images are obtained, using a computationally feasible pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 13 3 شماره
صفحات -
تاریخ انتشار 1999