Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement
نویسندگان
چکیده
BACKGROUND We investigated changes in the International Normalized Ratio (INR) and its measurement interval in patients with thromboembolic events who were treated by low intensity anticoagulation therapy after isolated mechanical aortic valve replacement. MATERIALS AND METHODS Seventy-seven patients who underwent surgery from June 1990 to September 2006 were enrolled in the study and observed until August 2008. The patients were followed up at 4~8 week intervals and their warfarin (Coumadin)® dosage was adjusted aiming for a target range of INR 1.5~2.5. The rate of thromboembolic events was obtained. Changes in the mean INR and INR measurement interval were comparatively analyzed between the normal group (event free group, N=52) who had no anticoagulation-related complications and the thromboembolic group (N=10). Hospital records were reviewed retrospectively. RESULTS The observation period was 666.75 patient-years. Thromboembolic events occurred in 10 patients. The linearized occurrence rate of thromboembolism was 1.50%/patient-years. Actuarial thromboembolism-free rates were 97.10±2.02% at 5 years, 84.30±5.22% at 10 years, and 67.44±12.14% at 15 years. The percentages of INR within the target range and mean INR were not statistically significantly different for the normal and thromboembolic groups. However, the mean INR during the segmented period just before the events showed a significantly lower level in the thromboembolic group (during a 4 month period: normal group, 1.86±0.14 vs. thromboembolic group, 1.50±0.28, p<0.001). The mean intervals of INR measurement during the whole observation period showed no significant differences between groups, but in the segmented period just before the events, the interval was significantly longer in thromboembolic group (during a 6 month period: normal group, 49.04±9.47 days vs. thromboembolic group, 65.89±44.88 days, p<0.01). CONCLUSION To prevent the occurrence of thromboembolic events in patients who receive isolated aortic valve replacement and low intensity anticoagulation therapy, we suggest that it would be safe to maintain an INR level above 1.8 and to measure the INR at least every 7~8 weeks.
منابع مشابه
Medium and long-term follow-up in Chinese patients receiving low intensity warfarin anticoagulation treatment with low International Normalized Ratio (INR) after mechanical mitral valve replacement
Anticoagulation therapy was generally used in patients receiving mechanical mitral valve replacement. However, due to the increased risk of bleeding of anticoagulation therapy, it is important to control the International Normalized Ratio (INR) in a lower range to decrease the risk of bleeding. Therefore, the aim of this study was to investigate to which level the INR should be controlled and e...
متن کاملINR self-management permits lower anticoagulation levels after mechanical heart valve replacement.
BACKGROUND The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of pr...
متن کاملAntithrombotic and Thrombolytic Therapy for Valvular Disease
We were pleased to read the article by Whitlock et al 1 in the February 2012 supplement issue of CHEST . They concluded, “In patients with a mechanical mitral valve (both the aortic and mitral position), we suggest [vitamin K antagonist] therapy with a target [international normalized ratio (INR)] of 3.0 (range, 2.5-3.5).” 1 However, we have several concerns about their conclusion. First, thro...
متن کاملMechanical Aortic Valve Replacement in Young Women Planning on Pregnancy
Methods A comprehensive pre-operative counseling protocol to guide choice of replacement device was developed. The pre-operative anticoagulation trial to determine the warfarin daily dosage needed to reach target international normalized ratio (INR) represented the main stem of such protocol. Pregnancies on low-dose anticoagulation therapy (target INR: 1.5 to 2.5) were allowed in a highly selec...
متن کاملAnticoagulant therapy in Japanese patients with mechanical mitral valves.
There are no guidelines for the optimal therapeutic range of anticoagulant therapy in Japanese patients with mechanical heart valves. A total of 214 patients were followed retrospectively after mitral mechanical valve replacement (mean duration of follow-up, 4.8 years; total duration of follow-up, 1,027 patient-years). The target range of the international normalized ratio (INR) for oral antico...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 44 شماره
صفحات -
تاریخ انتشار 2011