Stability of trisodium citrate and gentamicin solution for catheter locks after storage in plastic syringes at room temperature.
نویسندگان
چکیده
BACKGROUND Catheter-related infections are a major problem for hemodialysis patients with central venous catheters for vascular access. Catheter lock solutions containing an anticoagulant are used to maintain the patency of the catheter between hemodialysis sessions. There is evidence that the use of lock solutions containing an antibiotic is associated with lower rates of infection but also that these solutions can kill microbes in colonized catheters and thus avoid the risks and costs associated with replacing the catheter. OBJECTIVE This stability study was conducted to determine whether an extemporaneously prepared gentamicin-citrate catheter lock solution would retain its potency over time, thus allowing for advance preparation of the solution. METHODS Catheter lock solutions containing gentamicin alone, citrate alone, and the combination of gentamicin and citrate were prepared aseptically and packaged in polyethylene syringes. The syringes were stored at room temperature. At timed intervals over 112 days, samples were withdrawn for analysis by means of validated high-performance liquid chromatography. RESULTS None of the 3 lock solutions showed any evidence of degradation during the 112-day observation period. In the formulation containing both gentamicin 2.5 mg/mL and sodium citrate 40 mg/mL (4%), there was no change in the concentration of either gentamicin (p = 0.34) or citrate (p = 0.55). Linear regression analysis of the concentration-time data for the combined formulation showed that 99.97% of the labelled amount of gentamicin and 101.30% of the labelled amount of citrate remained at day 112. The lower limit of the 95% confidence intervals indicated that more than 98.17% of the gentamicin and more than 99.57% of the citrate remained on day 112. CONCLUSION The results of this study will allow pharmacies to extemporaneously compound the combined gentamicin-citrate catheter lock solution in advance of use. The method described here will yield a stable product for use in clinical applications.
منابع مشابه
Is Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis
Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...
متن کاملStability of levetiracetam oral solution repackaged in oral plastic syringes.
PURPOSE The long-term stability of levetiracetam solution in oral syringes was investigated in order to define a suitable beyond-use date and demonstrate the feasibility of storing prepared syringes for extended periods as an alternative to commercial levetiracetam unit dose cups. METHODS Levetiracetam oral solution (100 mg/mL) was drawn into 1- and 10-mL amber polypropylene oral syringes. Tr...
متن کاملStability of diluted ketamine packaged in glass vials.
Ketamine hydrochloride for injection is a rapid-acting general anesthetic agent. To avoid an out-of-stock situation for this drug at the desired concentration for administration to patients (10 mg/mL), the author’s institution investigated the chemical stability of a diluted solution of the concentrated formulation (50 mg/mL), packaged for storage in glass vials. The only difference between the...
متن کاملEffects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.
BACKGROUND Although plastic arterial sampling syringes are now commonly used, the effects of sample storage time and temperature on blood gas tensions are poorly described for samples with a high oxygen partial pressure (PaO2) taken with these high density polypropylene syringes. METHODS Two ml samples of tonometered whole blood (PaO2 86.7 kPa, PaCO2 4.27 kPa) were placed in glass syringes an...
متن کاملConcentrated Sodium Citrate (23%) for Catheter Lock.
For chronic central venous dialysis catheters, the standard method for maintaining catheter patency between treatments is to instill (lock) catheters with 5000 - 10 000 units of heparin in each lumen. Sodium citrate (citrate) is an anticoagulant with intrinsic antibacterial activity (at 20% concentration or higher). Citrate has only transient anticoagulant effects if accidentally infused to the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Canadian journal of hospital pharmacy
دوره 63 4 شماره
صفحات -
تاریخ انتشار 2010